Bosch B18IF800SP Installation Instructions - Page 7
Connecting the power, en-us
View all Bosch B18IF800SP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Connecting the power , WARNING: ■ Avoid the risk of an electric shock! ■ Insert into a grounded 3-phase socket. Never remove grounding phase. Do not use any adapters. Do not use any extension cables. ■ Non-compliance with these instructions may result in death, fire or an electric shock. Improper connection of the protective conductor may result in an electric shock. If you are in doubt whether the appliance has been grounded properly, have the appliance tested by a qualified electrician or service technician. The socket must be near the appliance and also freely accessible following installation of the appliance. The appliance complies with protection class I. Connect the appliance to 115 V/60 Hz alternating current via a correctly installed socket with protective conductor. The socket must be fused with a 10 to 16 A fuse. The appliance comes with a UL registered 3-wire power cord. The appliance requires a 3-pole socket. Please observe the following table with regard to this: Appliance Refrigerator 30" Maximum Simultaneous Load 2.0 Ampere Freezer 18" (*) 3.5 Ampere (*) incl. Ice Maker Check on the rating plate whether the indicated voltage and current type correspond with the values of your power supply. The location of the rating plate can be found in the chapter "Customer service". , WARNING: Never connect the appliance to electronic energy saver plugs. Our appliances can be used with mains and sine-controlled inverters. Mainscontrolled inverters are used for photovoltaic systems which are connected directly to the national grid. Sine-controlled inverters must be used for isolated applications (e.g. on ships or in mountain lodges) which are not connected directly to the national grid. en-us Connecting the water , CAUTION: Only connect the appliance to drinking water! The water may be connected only by a competent fitter according to the local regulations of the appropriate water supply company. A cold water connection is necessary for operating the automatic ice maker. The water pressure must be between 25 and 120 p.s.i. (1,72 and 8,25 bar). The installation must correspond to the local plumbing regulations. A separate shut-off valve should be installed in the cold water inflow. The shut-off valve should not be located behind the appliance. It is recommended that you mount the shut-off valve directly next to the appliance or at another place which is easily accessible. When installing the water connection, pay attention to the permissible installation area for the water mains. For connection to the drinking water mains use only water pipes which are suitable for drinking water. Observe national regulations and the connection conditions of the local water supply companies. When installing the water connection, observe the permitted installation areas for the pipe. For the permitted installation areas and dimensions see "Dimensions of the installation niche". Maximum outer diameter of the water pipe (without fittings): 3/8" (9.5 mm). 7