24. Reinstall the dryer door by sliding it onto the hinge pins. Avoid allowing the four plastic bushings to fall off the hinge pins. If any fall off, reinstall them on the hinge pins prior to reinstalling the dryer door. reinstall the dryer door 25. Reinstall the hinge cover plate removed in step 4. Insert and tighten the 4 screws holding the hinge cover plate in place. reinstall four screws and tighten securely 26. Install the plastic cover plate over the original hinge position at the right hand side of the dryer door opening. Insert and tighten the two screws holding the plate in place. 27. Test that the door opens and closes properly. The door should latch securely. The hinge reversal process is complete. Minimum Distances Important information concerning minimum distances: - Depending on the location of the exhaust air connection, an additional minimum distance of 5½ inch (14 cm) must be provided on this side, the side the connection is on, for ducts/brackets (see page 19). - Benefits of maintaining greater distance (clearances) than the minimum shown include: S more air cools the dryer, keeps the dryer from overheating, and improves drying performance. S reduction of the risk of mold formation behind the appliance. S reduced noise transmission S facilitation of installation and service. - If the dryer is installed in a small room, the doors of the room must be fitted with vents of the specified minimum size. Refer to the following illustrations of enclosed installations for additional information. - Allow additional clearance for door, wall and window molding where necessary. Installation Types Observe the following minimum clearances between the dryer and adjacent surfaces for all installation types. Minimum Installation Clearances A Sides B Top C Rear* D Front 0.25 in. (6.4 mm) 0.25 in. (6.4 mm) 5.25 in. (13.4 cm) 0.50 in. (12.8 mm) * as close to wall as venting or water connection will allow. If installed with a washer, the larger rear clearance for dryer venting is required for the laundry pair. q Units are designed so that the dryer can be stacked on top of the washer using one of the stacking kits shown on page 19. q Units are designed to allow for under-counter installation See required dimensions in undercounter installation section on page 12. Height measurements shown in this section are with the dryer feet at minimum extension (turned in all the way up against the base of the dryer). Recessed or Closet Dimensions for installation in a closet or recessed area are shown in the illustration below. Closet Ventilation Requirements E Top 48 sq. in. (310 sq. cm) F Bottom 24 sq. in. (155 sq. cm) Required Installation Space G Height 37.25 in. (94.6 cm) H Width 27.50 in. (69.9 cm) I Depth 37.25 in. (94.6 cm) Mounted on Pedestal Dimensions for pedestal mounting installation are shown in the illustration below. J Required Installation Space G Height 52.25 in. (132.7 cm) H Width 27.50 in. (69.9 cm) I Depth 37.25 in. (94.6 cm) J Pedestal Ht. 15.0 in. (38.1 cm) i Appliance must not be mounted on a pedestal for under counter installations. 11