Brother International FAX-8650P Service Manual - Page 110
Time length from CML ON to CED
View all Brother International FAX-8650P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
Selector No. 1 2 3 4 5 6 7 8 WSW10 (Protocol definition 2) Function Setting and Specifications Switching of DPS, following the CML ON/OFF Time length from transmission of the last dial digit to CML ON Time length from CML ON to CNG transmission Time length from CML ON to CED transmission (except for facsimileto-telephone switching) No. of training retries Encoding system (Compression) MR MMR 0: No 0: 100 ms 0: 2 sec. 0: 0.5 sec. No. 5 6 00: 01: 10: 11: 0: Allowed 0: Allowed 1: Yes 1: 50 ms 1: 4 sec. 1: 2 sec. 1 time 2 times 3 times 4 times 1: Not allowed 1: Not allowed l Selector 1: Switching of DPS, following the CML ON/OFF Setting this selector to "1" automatically switches DPS following the CML ON/OFF operation. l Selector 2: Time length from transmission of the last dial digit to CML ON This selector sets the time length from when the equipment transmits the last dial digit until the CML relay comes on. l Selector 3: Time length from CML ON to CNG transmission This selector sets the time length until the equipment transmits a CNG after it turns on the CML relay. l Selector 4: Time length from CML ON to CED transmission This selector sets the time length until the equipment transmits a CED after it turns on the CML relay. This setting does not apply to switching between facsimile and telephone. l Selectors 5 and 6: No. of training retries These selectors set the number of training retries to be repeated before automatic fallback. l Selectors 7 and 8: Encoding system (Compression) This selector determines whether or not use of the MR/MMR coding system will be allowed. V - 23