Brother International FAX-8650P Service Manual - Page 138
Modem Attenuator, WSW41 takes effect only in the V. 34 mode.
View all Brother International FAX-8650P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 138 highlights
Selector No. 1 | 4 5 | 8 WSW41 (Function setting 19) Function Setting and Specifications Not used. Modem Attenuator No. 5 6 7 8 0000: 0001: 0010: 0011: 0100: | 1111: -10 dBm -11 dBm -12 dBm -13 dBm -14 dBm | -25 dBm NOTE: WSW41 takes effect only in the V. 34 mode. l Selectors 5 through 8: Modem Attenuator These selectors are used to adjust the transmitting level of the modem when the reception level at the remote station is improper due to line loss. This function applies to super G3 protocol signals. V - 51
V
- 51
WSW41
(Function setting 19)
Selector
No.
Function
Setting and Specifications
1
|
4
Not used.
5
|
8
Modem Attenuator
No. 5
6
7
8
0
0
0
0
:
-10 dBm
0
0
0
1
:
-11 dBm
0
0
1
0
:
-12 dBm
0
0
1
1
:
-13 dBm
0
1
0
0
:
-14 dBm
|
|
1
1
1
1
:
-25 dBm
NOTE:
WSW41 takes effect only in the V. 34 mode.
Selectors 5 through 8:
Modem Attenuator
These selectors are used to adjust the transmitting level of the modem when the reception level at
the remote station is improper due to line loss.