Campbell Scientific Vibrating CRVW3 3-Channel Vibrating-Wire Datalogger - Page 96

Field Deployment of the, CRVW3, CRVW3 On, site Maintenance Visits, DevConfig

Page 96 highlights

CRVW3 3-Channel Vibrating-Wire Datalogger Once you have arrived at the site, review physical installation and hardware configuration issues that are detailed in Section 8.2, Field Deployment of the CRVW3. Refer to the maintenance items listed in Section 12.2, CRVW3 Onsite Maintenance Visits. Connect to the CRVW3 with a USB cable and DevConfig then use the DataMonitor tab and Troubleshoot tab to investigate how the measurements of the sensors are working or not (see Section 8.2.8.2, Validation with DevConfig). Compare the current spectrum with a baseline spectrum saved during maintenance (see Section 12.1.2, Sensor Spectrum Checks). Refer to Section 10, Complex (Large) Radio Networks, for details that will help troubleshoot radio connectivity problems. Use a portable base station (RF450 and laptop) to ensure you can communicate with the CRVW3 over its radio. It may be necessary to visit the base station or a repeater station to fully investigate radio network problems. Contact your local Campbell Scientific support representative for additional help when troubleshooting problems with CRVW3 operation or radio connectivity. 86

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

CRVW3 3-Channel Vibrating-Wire Datalogger
Once you have arrived at the site, review physical installation and hardware
configuration issues that are detailed in Section 8.2,
Field Deployment of the
CRVW3
. Refer to the maintenance items listed in Section 12.2,
CRVW3 On-
site Maintenance Visits
.
Connect to the CRVW3 with a USB cable and
DevConfig
then use the
DataMonitor
tab and
Troubleshoot
tab to investigate
how the measurements of the sensors are working or not (see Section 8.2.8.2,
Validation with DevConfig
). Compare the current spectrum with a baseline
spectrum saved during maintenance (see Section 12.1.2,
Sensor Spectrum
Checks
).
Refer to Section 10,
Complex (Large) Radio Networks
, for details that will help
troubleshoot radio connectivity problems. Use a portable base station (RF450
and laptop) to ensure you can communicate with the CRVW3 over its radio. It
may be necessary to visit the base station or a repeater station to fully
investigate radio network problems.
Contact your local Campbell Scientific support representative for additional
help when troubleshooting problems with CRVW3 operation or radio
connectivity.