Casio XJ-A240 User Manual - Page 38

Indicator/Error Message, Description and Required Action, There is some problem

Page 38 highlights

Indicator/Error Message POWER : Amber flashing  Red steady TEMP : Red steady LAMP : Red steady Message : There is a problem with the fan. The projector will turn off. POWER : Amber flashing  Red steady TEMP : Red steady LAMP : - Message : A system problem has occurred. The projector will turn off. Description and Required Action Power has turned off automatically due to a fan problem. Confirm that the POWER/STANDBY indicator is lit red (without flashing) and that the fan has stopped. After checking the POWER/STANDBY indicator, disconnect the power cord from the projector and wait for all of the projector's indicators to go out. Next, reconnect the power cord and turn projector power back on. If the error occurs again when you turn power back on, contact your retailer or nearest authorized CASIO Service Center. Power has turned off automatically due to a system problem. After confirming that the POWER/STANDBY indicator is lit red (without flashing), disconnect the power cord from the projector and wait for all of the projector's indicators to go out. Next, reconnect the power cord and turn the projector back on. If the error occurs again when you turn power back on, contact your retailer or nearest authorized CASIO Service Center. POWER TEMP LAMP Message : Green steady :- :- : A system problem has occurred. Normal projection is not possible. A system problem has occurred, which may cause problems with some functions. Turn off the projector, disconnect the power cord from the projector and wait for all of the projector's indicators to go out. Next, reconnect the power cord and turn the projector back on. If the error occurs again when you turn power back on, contact your retailer or nearest authorized CASIO Service Center. Press the [ESC] key to clear the warning message. POWER : Green steady TEMP : - LAMP : - Message : There is some problem with the system. The audio function may not operate correctly. POWER : Green steady TEMP : - LAMP : - Message : There is a problem with the USB port. The USB connection was terminated because of a problem with the USB port. To use the USB function, turn off the projector and then turn it back on again. If the error occurs again when you turn power back on, contact your retailer or nearest authorized CASIO Service Center. Press the [ESC] key to clear the warning message. POWER TEMP LAMP Message : Green steady :- :- : Zoom and focus cannot be performed for some reason. Try turning the projector off and then back on again. If this message reappears, request servicing. Zoom and focus cannot be performed due to some trouble in the optical drive circuit. Turn off the projector and then turn it back on again. If the error occurs again when you turn power back on, contact your retailer or nearest authorized CASIO Service Center. Press the [ESC] key to clear the warning message. 38

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

38
POWER
:
Amber flashing
Red steady
Power has turned off automatically due to a fan problem. Confirm that the
POWER/STANDBY indicator is lit red (without flashing) and that the fan
has stopped. After checking the POWER/STANDBY indicator, disconnect
the power cord from the projector and wait for all of the projector’s
indicators to go out. Next, reconnect the power cord and turn projector
power back on.
If the error occurs again when you turn power back on, contact your
retailer or nearest authorized CASIO Service Center.
TEMP
:
Red steady
LAMP
:
Red steady
Message
:
There is a problem with
the fan. The projector will
turn off.
POWER
:
Amber flashing
Red steady
Power has turned off automatically due to a system problem. After
confirming that the POWER/STANDBY indicator is lit red (without
flashing), disconnect the power cord from the projector and wait for all of
the projector’s indicators to go out. Next, reconnect the power cord and
turn the projector back on.
If the error occurs again when you turn power back on, contact your
retailer or nearest authorized CASIO Service Center.
TEMP
:
Red steady
LAMP
:–
Message
:
A system problem has
occurred. The projector
will turn off.
POWER
:
Green steady
A system problem has occurred, which may cause problems with some
functions. Turn off the projector, disconnect the power cord from the
projector and wait for all of the projector’s indicators to go out. Next,
reconnect the power cord and turn the projector back on.
If the error occurs again when you turn power back on, contact your
retailer or nearest authorized CASIO Service Center.
Press the [ESC] key to clear the warning message.
TEMP
:–
LAMP
:–
Message
:
A system problem has
occurred. Normal
projection is not possible.
POWER
:
Green steady
TEMP
:–
LAMP
:–
Message
:
There is some problem
with the system.
The audio function may
not operate correctly.
POWER
:
Green steady
The USB connection was terminated because of a problem with the USB
port. To use the USB function, turn off the projector and then turn it back
on again.
If the error occurs again when you turn power back on, contact your
retailer or nearest authorized CASIO Service Center.
Press the [ESC] key to clear the warning message.
TEMP
:–
LAMP
:–
Message
:
There is a problem with
the USB port.
POWER
:
Green steady
Zoom and focus cannot be performed due to some trouble in the optical
drive circuit. Turn off the projector and then turn it back on again.
If the error occurs again when you turn power back on, contact your
retailer or nearest authorized CASIO Service Center.
Press the [ESC] key to clear the warning message.
TEMP
:–
LAMP
:–
Message
:
Zoom and focus cannot
be performed for some
reason. Try turning the
projector off and then
back on again.
If this message reappears,
request servicing.
Indicator/Error Message