Dell OptiPlex GXi Service Manual (.pdf) - Page 56
Table 3-1., POST Beep Codes, Master DMA-register failure
View all Dell OptiPlex GXi manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Table 3-1. POST Beep Codes Beep Code Error Probable Causes 1-3 Monitor not detected Disconnected or faulty monitor 1-1-3 NVRAM write/read failure Defective system board 1-1-4 BIOS checksum failure Faulty BIOS or defective system board 1-2-1 Programmable interval-timer Defective system board failure 1-2-2 DMA initialization failure 1-2-3 1-3-1 1-3-2 1-3-3 DMA page register write/ read failure Main-memory refresh verification failure No memory installed Chip or data line failure in the first 64 KB of main memory Faulty or improperly seated DIMM or defective system board No memory installed or faulty or improperly seated DIMM Faulty or improperly seated DIMM 1-3-4 Odd/even logic failure in the first 64 KB of main memory 1-4-1 Address line failure in the first 64 KB of main memory 1-4-2 Parity failure in the first 64 KB of main memory 2-1-1 through 2-4-4 3-1-1 Bit failure in the first 64 KB of main memory Slave DMA-register failure Defective system board 3-1-2 Master DMA-register failure 3-1-3 Master interrupt-mask register failure 3-1-4 3-2-4 Slave interrupt-mask register failure Keyboard-controller test failure Faulty keyboard controller (defective system board) 3-2 Dell OptiPlex GXi Systems Service Manual