Chapter 7 Specifications Physical Table 7 Physical Specifications Item Size Weight Environmental Table 8 Environmental Specifications Item Temperature Humidity Altitude Operational Table 9 Operational Specifications Item Power Supplies Power Consumption Network Management Standards Measurement Height 14.9 cm (5.85 inches) Width 44.2 cm (17.4 inches) Depth 31.8 cm (12.5 inches) 26.5 KG (58 lbs.) maximum 6.3 KG (13.9 lbs.) chassis and fan tray 4.4 KG (9.6 lbs.) each power supply Measurement Operating: 0 to 40 ºC (32 to 104 ºF) Storage: 0 to 50 ºC (32 to 122 ºF) Minor alarm: 40 ºC Major alarm: 50 ºC Critical alarm: 60 ºC 5% to 95% (non-condensing) 3,048 m (10,000 feet), maximum Measurement Model HW-PSU-400- Input: 85-264 VAC, 50-60 Hz Output: 48 V, 8 A 460W (per power supply), maximum HTML Web-browser interface IEEE 802.1x, IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX, IEEE 802.3ab 1000BASE-T, IEEE 802.3z 1000BASE-SX Dell PowerConnect W-6000 Controller | Installation Guide Specifications | 29