Input Example racadm cmcchangeover NA NOTE: During a failover, the chassis power state on the OME - Modular GUI is displayed as "off". The original power state is displayed after the inventory is refreshed. config Description Synopsis Modifies the configuration properties of the management module. racadm config -g -o [-m ] Input Example racadm config -g -i -o • -g-Configuration group to which the object belongs • -o-Configuration object to configure • -i-Index of indexed group, which is used with -g and -o • -m-The module must have one of the following values: - storage-- where n=1 to 8 NOTE: The storage - option is available only for cfgStorageModule • -Value of the configuration object • Configure a single property of a group: racadm config -g cfgLanNetworking -o cfgDNSRacName NAME • Configure a single property of a group for a particular user: racadm config -g cfgUserAdmin -i 2 -o cfgUserAdminPassword PASSWORD connect Description Synopsis Connects to switch or blade serial console. The connect command is supported only on firmware interfaces. racadm connect [-b] -m Input Example • -b-Binary mode If -b is used, reset OME-Modular to terminate the connect. • -m-The option must be one of the following values: • server--where n = 1-8 • switch--where n = 1-6 CAUTION: When run from the OME-Modular serial console, the connect -b option stays connected until the management module resets or the serial console is terminated. This connection is a potential security risk. NOTE: The racadm connect to server prompts you to enter the iDRAC credentials for connecting to the server. • Connect to server 1 serial console: racadm connect -m server-1 RACADM sub command details 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

Input
racadm cmcchangeover
Example
NA
NOTE:
During a failover, the chassis power state on the OME - Modular GUI is displayed as "off". The original power
state is displayed after the inventory is refreshed.
config
Description
Modifies the configuration properties of the management module.
Synopsis
racadm config -g <group> -o <object> <value> [-m <module>]
racadm config -g <group> -i <index> -o <object> <value>
Input
-g
—Configuration group to which the object belongs
-o
—Configuration object to configure
-i
—Index of indexed group, which is used with
-g
and
-o
-m
—The
module
must have one of the following values:
- storage-<n>-
where n=1 to 8
NOTE:
The storage -<n> option is available only for
cfgStorageModule
<value>
—Value of the configuration object
Example
Configure a single property of a group:
racadm config -g cfgLanNetworking -o cfgDNSRacName NAME
Configure a single property of a group for a particular user:
racadm config -g cfgUserAdmin -i 2 -o cfgUserAdminPassword PASSWORD
connect
Description
Connects to switch or blade serial console. The
connect
command is supported only on firmware interfaces.
Synopsis
racadm connect [-b] -m <module>
Input
-b
—Binary mode
If
-b
is used, reset OME-Modular to terminate the
connect
.
-m
—The
<module>
option must be one of the following values:
server-<n>
—where n = 1-8
switch-<n>
—where n = 1-6
CAUTION:
When run from the OME–Modular serial console, the
connect -b
option stays
connected until the management module resets or the serial console is terminated. This
connection is a potential security risk.
NOTE:
The
racadm connect
to server prompts you to enter the iDRAC credentials for connecting
to the server.
Example
Connect to server 1 serial console:
racadm connect -m server-1