Dell PowerEdge MX7000 EMC OpenManage Enterprise Modular Edition Version 1.10.0 - Page 18

Synopsis, Input, Example, RACADM sub command details

Page 18 highlights

Synopsis Input Example racadm getpbinfo racadm getpbinfo racadm getpbinfo [Power Budget Status] System Input Power = 615 W (2098 BTU/h) Peak System Power = 628 W (2142 BTU/h) Peak System Power Timestamp = 11:37:36 08/08/2018 Minimum System Power = 606 W (2067 BTU/h) Minimum System Power Timestamp = 10:16:08 08/06/2018 Overall Power Health = Not OK Redundancy = No System Input Power Cap = Disabled Redundancy Policy = None Dynamic PSU Engagement Enabled = Not Applicable System Input Max Power Capacity = 11571 W Input Redundancy Reserve = Not Applicable Input Power Allocated to Servers = Not Applicable Input Power Allocated to Chassis Infrastructure = Not Applicable Total Input Power Available for Allocation = 2385 W (8137 BTU/h) Standby Input Power Capacity = Not Applicable Server Based Power Management Mode = Not Applicable Max Power Conservation Mode = Not Applicable Server Performance Over Power Redundancy = Not Applicable Power Available for Server Power-on = Not Applicable Extended Power Performance(EPP) Status = Not Applicable Available Power in EPP Pool = Not Applicable Used Power in EPP Pool = Not Applicable EPP Percent - Available = Not Applicable [Chassis Power Supply Status Table] Volts> PS1 PSU.Slot.1 Online V 3000 W PS2 PSU.Slot.2 Online V 3000 W PS3 PSU.Slot.3 Online V 3000 W PS4 PSU.Slot.4 Slot Empty A N/A PS5 PSU.Slot.5 Slot Empty A N/ A PS6 PSU.Slot.6 Slot Empty A 1.55 A 1.57 A 1.65 A N/A N/A N/A

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

Synopsis
racadm getpbinfo
Input
racadm getpbinfo
Example
racadm getpbinfo
[Power Budget Status]
System Input Power
= 615 W (2098 BTU/h)
Peak System Power
= 628 W (2142 BTU/h)
Peak System Power Timestamp
= 11:37:36 08/08/2018
Minimum System Power
= 606 W (2067 BTU/h)
Minimum System Power Timestamp
= 10:16:08 08/06/2018
Overall Power Health
= Not OK
Redundancy
= No
System Input Power Cap
= Disabled
Redundancy Policy
= None
Dynamic PSU Engagement Enabled
= Not Applicable
System Input Max Power Capacity
= 11571 W
Input Redundancy Reserve
= Not Applicable
Input Power Allocated to Servers
= Not Applicable
Input Power Allocated to Chassis Infrastructure = Not Applicable
Total Input Power Available for Allocation
= 2385 W (8137 BTU/h)
Standby Input Power Capacity
= Not Applicable
Server Based Power Management Mode
= Not Applicable
Max Power Conservation Mode
= Not Applicable
Server Performance Over Power Redundancy
= Not Applicable
Power Available for Server Power-on
= Not Applicable
Extended Power Performance(EPP) Status
= Not Applicable
Available Power in EPP Pool
= Not Applicable
Used Power in EPP Pool
= Not Applicable
EPP Percent - Available
= Not Applicable
[Chassis Power Supply Status Table]
<Name>
<Model>
<Power State>
<Input Current>
<Input
Volts>
<Output Rated
Power>
PS1
PSU.Slot.1
Online
1.55 A
226
V
3000
W
PS2
PSU.Slot.2
Online
1.57 A
227
V
3000 W
PS3
PSU.Slot.3
Online
1.65 A
227
V
3000
W
PS4
PSU.Slot.4
Slot Empty
N/A
N/
A
N/A
PS5
PSU.Slot.5
Slot Empty
N/A
N/
A
N/
A
PS6
PSU.Slot.6
Slot Empty
N/A
N/
A
N/A
[Server Module Power Allocation Table]
<Slot#>
<Server Name>
<Power State>
<Allocation>
<Priority>
<Blade Type>
1
SLOT-1
ON
605 W
1
PowerEdge MX840c
2
Extension (1)
N/A
N/A
N/
A
N/A
3
SLOT-3
ON
792 W
1
PowerEdge MX840c
4
Extension (3)
N/A
N/A
N/
18
RACADM sub command details