Dell PowerEdge MX7000 EMC OpenManage Enterprise Modular Edition Version 1.10.0 - Page 22

ping6, racreset, racresetcfg, serveraction

Page 22 highlights

Example To ping ip address 192.168.0.1 racadm ping 192.168.0.1 ping6 Description Synopsis Input Example Sends ICMP echo packets on the network. racadm ping6 -The IPv6 address of the remote endpoint to ping. To ping ipaddress FE80:0000:0000:0000:0202:B3FF:FE1E:8329 racadm ping6 FE80:0000:0000:0000:0202:B3FF:FE1E:8329 racreset Description Synopsis Resets the RAC. racadm racreset racresetcfg Description Synopsis Restores the RAC configuration to factory defaults. Before or after performing racresetcfg in the member chassis, go to the lead chassis and remove the member chassis from the MCM group. racadm racresetcfg Input • -f-Resets all management module configurations to the default configuration and preserves the userconfigured and network settings. Running the racresetcfg command results in the following: • Clears Management Module Configuration and resets to Initial settings. • Rediscovers iDRAC. NOTE: iDRAC discovery may take longer, as the Chassis may not receive the MDNS message from iDRAC immediately. • Removes the MCM grouping functionality. NOTE: The reset_config, reset_all, racresetcfg, FIPS_MODE ON/OFF workflow clear the database and the user information is not retained. Hence, configuration restoration is logged in DELL_INTERNAL_PROCESS. NOTE: If the member chassis undergoes a factory reset, it becomes a stand-alone chassis and not a member of the multi-chassis group. You can remove the member from the lead chassis. NOTE: After performing any reset operation, wait for the IP address before performing the reset operation again. serveraction Description Manages the server or storage power. Supported actions are: 22 RACADM sub command details

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

Example
To ping ip address 192.168.0.1
racadm ping 192.168.0.1
ping6
Description
Sends ICMP echo packets on the network.
Synopsis
racadm ping6 <ipaddress>
Input
<ipaddress>
—The IPv6 address of the remote endpoint to ping.
Example
To ping ipaddress FE80:0000:0000:0000:0202:B3FF:FE1E:8329
racadm ping6 FE80:0000:0000:0000:0202:B3FF:FE1E:8329
racreset
Description
Resets the RAC.
Synopsis
racadm racreset
racresetcfg
Description
Restores the RAC configuration to factory defaults.
Before or after performing
racresetcfg
in the member chassis, go to the lead chassis and remove the member
chassis from the MCM group.
Synopsis
racadm racresetcfg
Input
-f—Resets all management module configurations to the default configuration and preserves the user-
configured and network settings.
Running the
racresetcfg
command results in the following:
Clears Management Module Configuration and resets to Initial settings.
Rediscovers iDRAC.
NOTE:
iDRAC discovery may take longer, as the Chassis may not receive the MDNS message from iDRAC
immediately.
Removes the MCM grouping functionality.
NOTE:
The
reset_config
,
reset_all
,
racresetcfg
,
FIPS_MODE ON/OFF
workflow clear the database and the user
information is not retained. Hence, configuration restoration is logged in
DELL_INTERNAL_PROCESS
.
NOTE:
If the member chassis undergoes a factory reset, it becomes a stand-alone chassis and not a member of the
multi-chassis group. You can remove the member from the lead chassis.
NOTE:
After performing any reset operation, wait for the IP address before performing the reset operation again.
serveraction
Description
Manages the server or storage power. Supported actions are:
22