Dell PowerEdge MX7000 EMC OpenManage Enterprise Modular Edition Version 1.00.1 - Page 20

racreset, racresetcfg, serveraction

Page 20 highlights

Synopsis racadm ping6 Input Example -The IPv6 address of the remote endpoint to ping. To ping ipaddress FE80:0000:0000:0000:0202:B3FF:FE1E:8329 racadm ping6 FE80:0000:0000:0000:0202:B3FF:FE1E:8329 racreset Description Synopsis Resets the RAC. racadm racreset racresetcfg Description Synopsis Restores the RAC configuration to factory defaults. racadm racresetcfg Running the racresetcfg command results in the following: • Clears Management Module Configuration and resets to Initial settings. • Rediscovers iDRAC. NOTE: iDRAC discovery may take longer, as the Chassis may not receive the MDNS message from iDRAC immediately. • Removes the MCM grouping functionality. NOTE: The reset_config, reset_all, racresetcfg, FIPS_MODE ON/OFF workflow clear the database and the user information is not retained. Hence, configuration restoration is logged in DELL_INTERNAL_PROCESS. NOTE: If the member chassis undergoes a factory reset, it becomes a stand-alone chassis and not a member of the multi-chassis group. You can remove the member from the lead chassis. serveraction Description Synopsis Manages the server or storage power. Supported actions are: • powerdown-perform server power off • powerup-perform server power on • powercycle-perform server power cycle • hardreset-force hard server power reset • graceshutdown-perform graceful shutdown of server • reseat-perform a virtual reseat of a server/storage NOTE: This action requires -f option to force the action. • powerstatus-display current power status of server NOTE: This action is not allowed with -a option racadm serveraction -m racadm serveraction -a 20 RACADM sub command details

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

Synopsis
racadm ping6 <ipaddress>
Input
<ipaddress>
—The IPv6 address of the remote endpoint to ping.
Example
To ping ipaddress FE80:0000:0000:0000:0202:B3FF:FE1E:8329
racadm ping6 FE80:0000:0000:0000:0202:B3FF:FE1E:8329
racreset
Description
Resets the RAC.
Synopsis
racadm racreset
racresetcfg
Description
Restores the RAC
configuration
to factory defaults.
Synopsis
racadm racresetcfg
Running the
racresetcfg
command results in the following:
Clears Management Module
Configuration
and resets to Initial settings.
Rediscovers iDRAC.
NOTE:
iDRAC discovery may take longer, as the Chassis may not receive the MDNS message from iDRAC immediately.
Removes the MCM grouping functionality.
NOTE:
The
reset_config
,
reset_all
,
racresetcfg
,
FIPS_MODE ON/OFF
workflow
clear the database and the user
information is not retained. Hence,
configuration
restoration is logged in DELL_INTERNAL_PROCESS.
NOTE:
If the member chassis undergoes a factory reset, it becomes a stand-alone chassis and not a member of the multi-chassis
group. You can remove the member from the lead chassis.
serveraction
Description
Manages the server or storage power. Supported actions are:
powerdown
—perform server power
off
powerup
—perform server power on
powercycle
—perform server power cycle
hardreset
—force hard server power reset
graceshutdown
—perform graceful shutdown of server
reseat
—perform a virtual reseat of a server/storage
NOTE:
This action requires
-f
option to force the action.
powerstatus
—display current power status of server
NOTE:
This action is not allowed with -a option
Synopsis
racadm serveraction -m <module> <action>
racadm serveraction -a <action>
20
RACADM sub command details