Dell PowerEdge MX7000 EMC OpenManage Enterprise Modular Edition Version 1.00.1 - Page 26
cfgDNSDomainNameFromDHCP (Read or Write), cfgStorageModule
![]() |
View all Dell PowerEdge MX7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Default cfgDNSDomainNameFromDHCP (Read or Write) Description Legal Values Specifies that management module DNS domain name must be assigned from the network DHCP server. • 1 - True • 0 - False Default 0 This property is used only if cfgNicUseDhcp is set to 1(true), or if both cfgIPv6Enable and cfgIPv6AutoConfig are set to 1(true). The management module can obtain its DNS domain name from either a DHCP or DHCPv6 server, if all of the following properties are set to 1 (true): • cfgNicIPv4Enable • cfgNicUseDhcp • cfgIPv6Enable • cfgIPv6AutoConfig • cfgDNSDomainNameFromDHCP • cfgDNSDomainName (Read or Write) The network administrator must make sure that these DHCP servers are configured to provide the same DNS domain name to the management module, otherwise the domain name becomes unpredictable. cfgStorageModule Description Synopsis Input Example This command is used only with the getconfig command. • cfgStorageModuleStorageMode= • # cfgStorageModuleServiceTag= • cfgStorageModuleAssetTag= • cfgConnectedSlots= • cfgStorageModuleStorageMode=2 • # cfgStorageModuleServiceTag=MX0000 • cfgStorageModuleAssetTag= • cfgConnectedSlots=2,2,2,2,2,2,2,2 26 OME Modular property database group and object descriptions
![](/manual_guide/products/dell-poweredge-mx7000-emc-openmanage-enterprise-modular-edition-version-10010-chassis-racadm-command-line-reference-guide-c3df489/26.png)