Dell PowerEdge R415 Hardware Owner's Manual - Page 29
PS AC Current, Check PSU - power consumption
View all Dell PowerEdge R415 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code E161C E1624 E1625 E1626 E1629 E1632 Text Causes Corrective Actions Power Supply # (### W) lost AC power. Check PSU cables. Specified power supply is attached to the system, but it has lost its AC input. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 155. Lost power supply redundancy. Check PSU cables. The power supply subsystem is no longer redundant. If the remaining power supply fails, the system will shut down. See "Troubleshooting Power Supplies" on page 155. PS AC Current Power source is out of acceptable range. Check the AC power source. Power Supply The power supplies in the Ensure that power Mismatch. PSU1 system are not the same supplies with matching = ### W, PSU2 wattage. wattage are installed. See = ### W. the Technical Specifications outlined in your system's Getting Started Guide. Power required > PSU wattage. Check PSU and config. The system configuration requires more power than the power supplies can provide, even with throttling. Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. FailSafe The processors and Remove AC power to the event. Contact memory have been system for 10 seconds and support. throttled to keep system restart the system. power consumption below the maximum safe level with current power supply configuration. If the problem persists, see "Getting Help" on page 181. About Your System 29