Dell PowerEdge R740 EMC NVDIMM-N Persistent Memory User Guide - Page 22

BIOS Error Messages - specs

Page 22 highlights

Figure 13. System BIOS Settings screen BIOS Error Messages When BIOS detects an NVDIMM-N related error during POST, BIOS displays an F1/F2 prompt and a corresponding error message. Multiple messages will appear when multiple errors were detected. BIOS will also log an event for each error in the Server System Event Log (SEL) and Life Cycle Log (LCL). Please refer to the JEDEC JESD245B spec for more information on each NVDIMM-N related failure. NVDIMM-N [Location] is the memory slot location as shown in Figure 5. UEFI0302* NVDIMM-N Not Ready or Not Responding on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302* Save Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302* Restore Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302 Arm Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302* Erase Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302 Factory Default Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302 Set Event Notification Error on NVDIMM-N located at [Location]. 22 BIOS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53

Figure 13. System BIOS Settings screen
BIOS Error Messages
When BIOS detects an NVDIMM-N related error during POST, BIOS displays an F1/F2 prompt and a corresponding error message.
Multiple messages will appear when multiple errors were detected. BIOS will also log an event for each error in the Server System Event
Log (SEL) and Life Cycle Log (LCL). Please refer to the JEDEC JESD245B spec for more information on each NVDIMM-N related failure.
NVDIMM-N [Location] is the memory slot location as shown in Figure 5.
UEFI0302*
NVDIMM-N Not Ready or Not Responding on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the
server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302*
Save Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the
server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302*
Restore Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the
server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302
Arm Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the
server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302*
Erase Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the
server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302
Factory Default Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the
server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302
Set Event Notification Error on NVDIMM-N located at [Location].
22
BIOS