Dell PowerEdge R740 EMC NVDIMM-N Persistent Memory User Guide - Page 22
BIOS Error Messages - specs
View all Dell PowerEdge R740 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Figure 13. System BIOS Settings screen BIOS Error Messages When BIOS detects an NVDIMM-N related error during POST, BIOS displays an F1/F2 prompt and a corresponding error message. Multiple messages will appear when multiple errors were detected. BIOS will also log an event for each error in the Server System Event Log (SEL) and Life Cycle Log (LCL). Please refer to the JEDEC JESD245B spec for more information on each NVDIMM-N related failure. NVDIMM-N [Location] is the memory slot location as shown in Figure 5. UEFI0302* NVDIMM-N Not Ready or Not Responding on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302* Save Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302* Restore Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302 Arm Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302* Erase Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302 Factory Default Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302 Set Event Notification Error on NVDIMM-N located at [Location]. 22 BIOS