Dell PowerEdge R740 EMC NVDIMM-N Persistent Memory User Guide - Page 43

Installation, Verify Existing Filesystem, Read-Only Mode NVDIMM-N, Interleave, Interleave Setup

Page 43 highlights

Installation Dump the RHEL ISO onto the USB stick via dd command. # dd if=/home/dell/RHEL7.3.iso of=/dev/sdb bs=4M conv=noerror,sync BIOS boots the Linux kernel from USB. Follow the on-screen steps to finish installing RHEL. After the installation is completed, reboot the server. For detailed installation instructions, please refer to https://access.redhat.com/documentation/en-US/Red_Hat_Enterprise_Linux/7/ html/Installation_Guide/index.html Verify Existing Filesystem Press PowerOn button on the server When the OS is up running, $ su Verify contents stored on NVDIMM-Ns # cat /mnt/nvdimm0 # shutdown Read-Only Mode NVDIMM-N Press PowerON button on the server Follow the guidance in Section 4 to setup BIOS. Enable the Persistence Memory, disable "NVDIMM Interleave", enable "NVDIMM Read-Only". When OS is up and running, $ su To see whether it is writable # touch /mnt/nvdimm0/write.txt # shutdown Interleave For R740/R640, insert NVDIMM-Ns in memory slots of both CPU Sockets. For this example 6 NVDIMM-Ns are installed on CPU0, and 6 are installed on CPU1. Interleave Setup Press PowerOn button on the server Follow the guidance in Section 4 to setup BIOS. Enable the Persistence Memory, enable "NVDIMM Interleave", disable "NVDIMM Read-Only". Install RHEL or start OS if it is already installed Linux 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53

Installation
Dump the RHEL ISO onto the USB stick via
dd
command.
# dd if=/home/dell/RHEL7.3.iso of=/dev/sdb bs=4M conv=noerror,sync
BIOS boots the Linux kernel from USB.
Follow the on-screen steps to finish installing RHEL.
After the installation is completed, reboot the server.
For detailed installation instructions, please refer to
html/Installation_Guide/index.html
Verify Existing Filesystem
Press PowerOn button on the server
When the OS is up running,
$ su
Verify contents stored on NVDIMM-Ns
# cat /mnt/nvdimm0
# shutdown
Read-Only Mode NVDIMM-N
Press PowerON button on the server
Follow the guidance in Section 4 to setup BIOS.
Enable the Persistence Memory, disable “NVDIMM Interleave”, enable “NVDIMM Read-Only”.
When OS is up and running,
$ su
To see whether it is writable
# touch /mnt/nvdimm0/write.txt
# shutdown
Interleave
For R740/R640, insert NVDIMM-Ns in memory slots of both CPU Sockets. For this example 6 NVDIMM-Ns are installed on CPU0, and 6
are installed on CPU1.
Interleave Setup
Press PowerOn button on the server
Follow the guidance in Section 4 to setup BIOS.
Enable the Persistence Memory, enable “NVDIMM Interleave”, disable “NVDIMM Read-Only”.
Install RHEL or start OS if it is already installed
Linux
43