Dell PowerEdge R740 EMC NVDIMM-N Persistent Memory User Guide - Page 47
Linux Errata
View all Dell PowerEdge R740 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
Linux Errata Following errata effects RHEL 7.6: • Patch to make ndctl utility work can be downloaded from here https://access.redhat.com/solutions/3920221 • Red Hat Enterprise Linux 7.6 or later might lose access to the data on NVDIMM-N memory module after updating from NVDIMM-N firmware version 8860 to 9234 or later. To restore access to the data, in Red Hat Enterprise Linux 7.6 CommandLine Interface, login to root user and run the following commands: NOTE: Ensure that the RHEL 7.6 create-namespace patch above is installed. 1. ndctl disable-region all 2. ndctl disable-dimm all 3. ndctl zero-labels all 4. ndctl enable-dimm all 5. ndctl enable-region all 6. Recreate namespaces in the mode previously used (i.e. ndctl create-namespace --mode=devdax --align=4k) 7. Repeat the create-namespace command above for every NVDIMM-N installed. Linux 47