Dell PowerEdge R740 EMC NVDIMM-N Persistent Memory User Guide - Page 28
Event Message, Recommended Action, iDRAC NVDIMM-N Management
![]() |
View all Dell PowerEdge R740 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Table 10. NVDIMM-N Error Reporting (continued) ID Event Message Recommended Action MEM9050 The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot [location] has regained persistency and is available for use. No response action required. MEM9072 The system memory has faced an uncorrectable multi-bit memory error in the nonexecution path of a memory device at the location . If the issue persists, contact your service provider. To select a convenient contact method, see the product documentation available on the support site. BAT0015 The NVDIMM battery is low. Leave the server powered on to allow the NVDIMM-N Battery to charge. If the issue persists, contact your service provider. For information about removing and reinstalling the NVDIMM, see the system Owner's Manual on the support site. BAT0017 The NVDIMM battery has failed. Remove and reinstall the NVDIMM-N Battery. If the issue persists, contact your service provider. For information about removing and reinstalling the NVDIMM, see the system Owner's Manual on the support site. BAT0019 The NVDIMM battery is absent. Remove and reinstall the NVDIMM-N Battery. If the issue persists, contact your service provider. For information about removing and reinstalling the NVDIMM, see the system Owner's Manual on the support site. 28 iDRAC NVDIMM-N Management