Dell PowerEdge R740 EMC NVDIMM-N Persistent Memory User Guide - Page 49

Namespaces, Interleave sets

Page 49 highlights

Translation of ID to physical NVDIMM-N in host system can be seen below. Table 14. Translation of ID to physical NVDIMM-N in host system ID (Hex) 0x1 Decimal 16 Physical Location (L->R) Socket 0 , IMC0, Channel 0 , Slot 1 0x11 17 Socket 0 , IMC0, Channel 1 , Slot 1 0x21 33 Socket 0 , IMC0, Channel 2 , Slot 1 0x101 257 Socket 0 , IMC1, Channel 0 , Slot 1 0x111 273 Socket 0 , IMC1, Channel 1 , Slot 1 0x121 289 Socket 0 , IMC1, Channel 2 , Slot 1 0x1001 4097 Socket 1 , IMC0, Channel 0 , Slot 1 0x1011 4113 Socket 1 , IMC0, Channel 1 , Slot 1 0x1021 4129 Socket 1 , IMC0, Channel 2 , Slot 1 0x1101 4353 Socket 1 , IMC1, Channel 0 , Slot 1 0x1111 4369 Socket 1 , IMC1, Channel 1 , Slot 1 0x1121 4385 Socket 1 , IMC1, Channel 2 , Slot 1 Silk screen slot name A7 A8 A9 A10 A11 A12 B7 B8 B9 B10 B11 B12 Namespaces All Namespace names are automatically generated by ESXi when the NVDIMM-N modules are detected on startup. These Namespaces will persist over warm reset and cold boot of the system after first detection/creation. Figure 31. Namespaces Interleave sets If Interleaving is Disabled in BIOS F2 Setup, then each NVDIMM-N will be in an individual Interleave Set as seen in the GUI below. ESXi 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53

Translation of ID to physical NVDIMM-N in host system can be seen below.
Table 14. Translation of ID to physical NVDIMM-N in host system
ID (Hex)
Decimal
Physical Location (L->R)
Silk screen slot name
0x1
16
Socket 0 , IMC0, Channel 0 , Slot 1
A7
0x11
17
Socket 0 , IMC0, Channel 1 , Slot 1
A8
0x21
33
Socket 0 , IMC0, Channel 2 , Slot 1
A9
0x101
257
Socket 0 , IMC1, Channel 0 , Slot 1
A10
0x111
273
Socket 0 , IMC1, Channel 1 , Slot 1
A11
0x121
289
Socket 0 , IMC1, Channel 2 , Slot 1
A12
0x1001
4097
Socket 1 , IMC0, Channel 0 , Slot 1
B7
0x1011
4113
Socket 1 , IMC0, Channel 1 , Slot 1
B8
0x1021
4129
Socket 1 , IMC0, Channel 2 , Slot 1
B9
0x1101
4353
Socket 1 , IMC1, Channel 0 , Slot 1
B10
0x1111
4369
Socket 1 , IMC1, Channel 1 , Slot 1
B11
0x1121
4385
Socket 1 , IMC1, Channel 2 , Slot 1
B12
Namespaces
All Namespace names are automatically generated by ESXi when the NVDIMM-N modules are detected on startup. These Namespaces
will persist over warm reset and cold boot of the system after first detection/creation.
Figure 31. Namespaces
Interleave sets
If Interleaving is Disabled in BIOS F2 Setup, then each NVDIMM-N will be in an individual Interleave Set as seen in the GUI below.
ESXi
49