Figure 37. NVDIMM-N Errors Refer to table below for the Overall Health Status message shown on ESXi Web Client in the event of the following errors: Table 16. Overall Health Status message shown on ESXi Web Client Status Errors Save Error - pre OS boot Maintenance Needed Restore Error - pre OS boot Maintenance Needed Erase Error - pre OS boot Maintenance Needed Arm Error - pre OS boot Maintenance Needed Controller Error - pre OS boot Maintenance Needed Controller Error at OS run time No OHS error until next boot, logged in SEL real time Invalid Firmware or Firmware running from Backup Slot Maintenance Needed NVDIMM-N Battery Failure at OS run-time All Data Loss NVDIMM-N Battery Failure - pre OS boot Maintenance Needed All the above error messages are also accompanied by equivalent messages in the System Event Log and Lifecycle Controller Log as described in the Sections 5 and 6 of this User Guide. ESXi Errata None at this time ESXi 53