Dell PowerEdge R740 EMC NVDIMM-N Persistent Memory User Guide - Page 23

Table 9. BIOS Error messages with event ID's and event messages, UEFI0302, Event Message

Page 23 highlights

This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302 Set Energy Source Policy Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302 Firmware Operation Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0302* Persistency Lost Error on NVDIMM-N located at [Location]. This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the server. If the issue persists, replace the faulty memory module identified in the message. UEFI0303 Lifetime Percentage

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53

This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the
server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302
Set Energy Source Policy Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the
server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302
Firmware Operation Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the
server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0302*
Persistency Lost Error on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Remove input power to the system, reseat the NVDIMM-N module, and restart the
server. If the issue persists, replace the faulty memory module identified in the message.
UEFI0303
Lifetime Percentage <= 5% on NVDIMM-N located at [Location]. The identified NVDIMM-N module is approaching the end of
its functional life.
Please plan to replace the NVDIMM-N module during the next scheduled maintenance. For more information, please refer to the server
Installation and Service Manual.
UEFI0304
Unable to enable the NVDIMM-N Save operation because Server is not Armed. All NVDIMM-N modules will be set to write-
protect mode. Please verify that the battery is operational, and that the server has sufficient power to support this configuration.
UEFI0304
Unable to enable the NVDIMM-N Save operation because Battery is not present. All NVDIMM-N modules will be set to write-
protect mode. Please verify that the battery is operational, and that the server has sufficient power to support this configuration.
UEFI0304
Unable to enable the NVDIMM-N Save operation because Battery is not ready. All NVDIMM-N modules will be set to write-
protect mode. Please verify that the battery is operational, and that the server has sufficient power to support this configuration.
UEFI0304
Unable to enable the NVDIMM-N Save operation because Server is not Armed. All NVDIMM-N modules will be set to write-
protect mode. Please verify that the battery is operational, and that the server has sufficient power to support this configuration, and that
NVDIMM Write-Protect mode has not be enabled in BIOS Setup.
UEFI0340
NVDIMM-N Running from Backup Firmware Image at [Location].
Update the NVDIMM-N to the latest firmware. If the issue persists, replace the faulty memory module identified in the message.
UEFI0341*
NVDIMM-N Lifetime Percentage <= 1% on NVDIMM-N located at [Location].
This NVDIMM-N module will be set to read only mode. Replace the NVDIMM-N module.
The following two BIOS messages are modular specific and will only be seen on an NVIDMM equipped server in the event that there are
no management modules installed in the modular chassis or the installed management modules are not capable of detecting an power loss
event.
Table 9. BIOS Error messages with event ID's and event messages
ID
Event Message
UEFI0364*
Unable to detect chassis power loss,
memory may not be persistent.
Ensure there are two functional chassis management modules. If there is only
a single chassis management module, only perform a firmware update on it
when server modules with persistent memory are powered off.
UEFI0365
Chassis is able to detect power loss,
memory is persistent.
No response action required.
*
Errors marked with an asterisk may result in data loss.