Dell PowerStore 1200T EMC PowerStore Release Notes for PowerStore OS Version 3 - Page 12
Chrome or Microsoft Edge. Or, clear the, You cannot issue Swagger UI
View all Dell PowerStore 1200T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Issue ID MDT-163489 MDT-261523 MDT-362809 MDT-130894 MDT-266683 MDT-153026 MDT-410197 Functional Area Description Workaround/Resolution PowerStore Manager (GUI) PowerStore Manager(GUI) PowerStore Manager (GUI) PowerStore REST API PowerStore REST API Security Storage - Block When a node is replaced, the new node hardware information does not appear in PowerStore Manager immediately. If Mozilla Firefox is used to upgrade a PowerStore cluster to PowerStore 2.0, a browser cache issue might occur that causes the names of some buttons and labels to be displayed as object names instead of the correct button or label names. Some text editors may append line end (\n) at the end of a certificate when opening the certificate file. The certificate is regarded as an invalid certificate due to the trailing space of the certificate. Two invalid resource_types, FEPort and Initiator, may be returned by the event and alert APIs. You cannot issue Swagger UI commands with Operator, Storage Administrator, and VM Administrator roles. You must log in with the higherlevel Administrator role if you want to complete tasks such as fetching or reading data from PowerStore. When a drive is inserted into an appliance, it will take time for D@RE to unlock it. Most drives take a few minutes. However, it takes more time for a ColdStream drive to unlock. The time is proportional to the size of the Intel Optane SCM drive, for example, 7 minutes for 375 GB, 15 minutes for 750 GB, and 27 minutes for 1.5TB. If you pull a drive out before it is unlocked, the drive will appear as disconnected. However, the drive will not be automatically removed from the appliance. Failed to modify a volume and set its "replication destination property" to false at the same time on PowerStore Manager. After replacing a node, wait up to 30 minutes for the PowerStore Manager screen to reflect the update. Use a different browser such as Google Chrome or Microsoft Edge. Or, clear the browser cache in Firefox. For instructions, see the KB article "How to clear the Firefox cache" on the Mozilla Firefox support site. Use an editor that does not append line end (\n) at the end. For example, using Notepad works fine, but using Notepad++ to open a certificate file would require manual removal of the line end. Events or alerts with resource_type FEPort or Initiator should ignore the resource_type values. External OpenAPI clients must disable validation for the event and alert APIs with resource_types of FEPort or Initiator. Customers can login in as administrator to use the swagger panel in PowerStore Manager. If you intend to use the drive, re-insert the drive and let the DARE unlock complete. If you intend to stop using the drive, re-insert the drive, wait for enough time (time to unlock plus about 1 minute for other overhead), and then remove the drive. The drive will then become disconnected and automatically removed from the system. Set the volume's "replication destination property" to false firstly then modify its other properties on PowerStore Manager. 12 Known Issues