Dell PowerStore 1200T EMC PowerStore Release Notes for PowerStore OS Version 3 - Page 16

Limitations

Page 16 highlights

Issue ID MDT-119414 Functional Area Virtualization Description Workaround/Resolution Deploying a VM fails, and checking the vvold.log vCenter log file reveals the following messages: 2019-11-15T05:24:35.161Z info vvold[2112740] [Originator@6876 sub=Default] VVolAbandonedObjectScan::ProcessNa mespace examining namespace /vmfs/volumes// Try to deploy the VM again. For more information, see the Dell knowledge base article 000132277 PowerStore: VM deployment can fail with "A general system error occurred." and 2019-11-15T05:24:35.318Z warning vvold[2112740] [Originator@6876 sub=Libs] 2112740:VVOLLIB : VVolLib_OpenObjectTrackingFile:11348 : VVolLib_OpenObjectTrackingFile: Failed to open object tracking file /vmfs/volumes// /.vvolObjList with error 6 where is the UUID of the storage container and is the alphanumeric identifier of the config-vVol of the VM. Limitations The following limitations exist in this release. For a complete list of PowerStore limitations see the: PowerStore Simple Support Matrix located on the PowerStore documentation page at: https://www.dell.com/powerstoredocs 16 Limitations

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

16
Limitations
Issue ID
Functional
Area
Description
Workaround/Resolution
MDT-119414
Virtualization
Deploying a VM fails, and checking the
vvold.log vCenter log file reveals the
following messages:
2019-11-15T05:24:35.161Z info
vvold[2112740] [Originator@6876
sub=Default]
VVolAbandonedObjectScan::ProcessNa
mespace examining namespace
/vmfs/volumes/<storage-container-
identifier>/<vvol-identifier>
and
2019-11-15T05:24:35.318Z warning
vvold[2112740] [Originator@6876
sub=Libs] 2112740:VVOLLIB :
VVolLib_OpenObjectTrackingFile:11348
: VVolLib_OpenObjectTrackingFile:
Failed to open object tracking file
/vmfs/volumes/<storage-container-
identifier>/<vvol-identifier>
/.vvolObjList with error 6
where <storage-container-identifier> is
the UUID of the storage container and
<vvol-identifier> is the alphanumeric
identifier of the config-vVol of the VM.
Try to deploy the VM again. For more
information, see the Dell knowledge base
article 000132277 PowerStore: VM
deployment can fail with “A general
system error occurred.”
Limitations
The following limitations exist in this release. For a complete list of PowerStore limitations see the: PowerStore
Simple Support Matrix located on the PowerStore documentation page at: