Dell PowerStore 1200T EMC PowerStore Release Notes for PowerStore OS Version 3 - Page 14

Virtual Distributed Switches to vSphere, Due to VMware bug DCPN 00091955

Page 14 highlights

Issue ID MDT-345741 MDT-289213 MDT-148608 MDT-153771 MDT-256673 MDT-377648 MDT-336285 Functional Area Support SupportAssist SupportAssist SupportAssist SupportAssist Virtualization Virtualization Description Workaround/Resolution The svc_dc upload script fails with the error "No path was found for the data collection." Wait five minutes and retry the svc_dc upload script. While attempting to upload data to SupportAssist, a node failover or node reboot occurred. Because of the node failover, or reboot it was unclear if the data successfully uploaded to SupportAssist. Upload the data to SupportAssist again once the failover, or reboot has completed. Attempts to upload Support Materials fail. SupportAssist is unable to upload files when there is insufficient free space in the system partition. Delete old Data Collections to increase the available space in the file system so that SupportAssist can make a backup copy of the file for upload. Enabling either Direct connect with remote access or Gateway connect with remote access may fail. If enabling either higher tier type, Direct connect with remote access or Gateway connect with remote access fails, wait for the backend issue to clear, then do the following: 1. Enable the related lower tier type, Direct connect without remote access or Gateway connect without remote access. 2. Disable the related lower tier type. 3. Re-enable the higher tier type, Direct connect with remote access or Gateway connect with remote access type. If the issue persists, contact your service provider. Cannot enable the SRS gateway on an appliance. Version 3.48 of the SRS gateway has an issue with connectivity from some PowerStore systems. Use a different version of the SRS gateway. Due to VMware bug DCPN 00091955, vVol migration sessions may sometimes go into a system_paused state. In VMware, perform a compute vMotion, or power off and power on the virtual machine to force the ESXi host to bind to the vVols. Once you have completed those steps, the migration sessions can be resumed. Migrating NSX-T from NSX-T managed Virtual Distributed Switches to vSphere Distributed Switches is not currently supported for PowerStore X cluster environments enabled with VMware NSX-T Data Center. Do not migrate NSX-T from dedicated NSX-T-managed Virtual Distributed Switches until the PowerStore X cluster is upgraded to a software version that supports vSphere Distributed Switches for PowerStore X cluster environments enabled with VMware NSX-T Data Center. 14 Known Issues

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

14
Known Issues
Issue ID
Functional
Area
Description
Workaround/Resolution
MDT-345741
Support
The svc_dc upload script fails with the
error "No path was found for the data
collection."
Wait five minutes and retry the svc_dc
upload script.
MDT-289213
SupportAssist
While attempting to upload data to
SupportAssist, a node failover or node
reboot occurred. Because of the node
failover, or reboot it was unclear if the
data successfully uploaded to
SupportAssist.
Upload the data to SupportAssist again
once the failover, or reboot has
completed.
MDT-148608
SupportAssist
Attempts to upload Support Materials
fail. SupportAssist is unable to upload
files when there is insufficient free
space in the system partition.
Delete old Data Collections to increase
the available space in the file system so
that SupportAssist can make a backup
copy of the file for upload.
MDT-153771
SupportAssist
Enabling either Direct connect with
remote access or Gateway connect
with remote access may fail.
If enabling either higher tier type, Direct
connect with remote access or Gateway
connect with remote access fails, wait
for the backend issue to clear, then do
the following:
1. Enable the related lower tier type,
Direct connect without remote access or
Gateway connect without remote access.
2. Disable the related lower tier type.
3. Re-enable the higher tier type, Direct
connect with remote access or Gateway
connect with remote access type.
If the issue persists, contact your service
provider.
MDT-256673
SupportAssist
Cannot enable the SRS gateway on an
appliance. Version 3.48 of the SRS
gateway has an issue with connectivity
from some PowerStore systems.
Use a different version of the SRS
gateway.
MDT-377648
Virtualization
Due to VMware bug DCPN 00091955,
vVol migration sessions may sometimes
go into a system_paused state.
In VMware, perform a compute vMotion,
or power off and power on the virtual
machine to force the ESXi host to bind to
the vVols. Once you have completed
those steps, the migration sessions can
be resumed.
MDT-336285
Virtualization
Migrating NSX-T from NSX-T managed
Virtual Distributed Switches to vSphere
Distributed Switches is not currently
supported for PowerStore X cluster
environments enabled with VMware
NSX-T Data Center.
Do not migrate NSX-T from dedicated
NSX-T-managed Virtual Distributed
Switches until the PowerStore X cluster
is upgraded to a software version that
supports vSphere Distributed Switches
for PowerStore X cluster environments
enabled with VMware NSX-T Data
Center.