Dell PowerStore 1200T EMC PowerStore Release Notes for PowerStore OS Version 3 - Page 14
Virtual Distributed Switches to vSphere, Due to VMware bug DCPN 00091955
View all Dell PowerStore 1200T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Issue ID MDT-345741 MDT-289213 MDT-148608 MDT-153771 MDT-256673 MDT-377648 MDT-336285 Functional Area Support SupportAssist SupportAssist SupportAssist SupportAssist Virtualization Virtualization Description Workaround/Resolution The svc_dc upload script fails with the error "No path was found for the data collection." Wait five minutes and retry the svc_dc upload script. While attempting to upload data to SupportAssist, a node failover or node reboot occurred. Because of the node failover, or reboot it was unclear if the data successfully uploaded to SupportAssist. Upload the data to SupportAssist again once the failover, or reboot has completed. Attempts to upload Support Materials fail. SupportAssist is unable to upload files when there is insufficient free space in the system partition. Delete old Data Collections to increase the available space in the file system so that SupportAssist can make a backup copy of the file for upload. Enabling either Direct connect with remote access or Gateway connect with remote access may fail. If enabling either higher tier type, Direct connect with remote access or Gateway connect with remote access fails, wait for the backend issue to clear, then do the following: 1. Enable the related lower tier type, Direct connect without remote access or Gateway connect without remote access. 2. Disable the related lower tier type. 3. Re-enable the higher tier type, Direct connect with remote access or Gateway connect with remote access type. If the issue persists, contact your service provider. Cannot enable the SRS gateway on an appliance. Version 3.48 of the SRS gateway has an issue with connectivity from some PowerStore systems. Use a different version of the SRS gateway. Due to VMware bug DCPN 00091955, vVol migration sessions may sometimes go into a system_paused state. In VMware, perform a compute vMotion, or power off and power on the virtual machine to force the ESXi host to bind to the vVols. Once you have completed those steps, the migration sessions can be resumed. Migrating NSX-T from NSX-T managed Virtual Distributed Switches to vSphere Distributed Switches is not currently supported for PowerStore X cluster environments enabled with VMware NSX-T Data Center. Do not migrate NSX-T from dedicated NSX-T-managed Virtual Distributed Switches until the PowerStore X cluster is upgraded to a software version that supports vSphere Distributed Switches for PowerStore X cluster environments enabled with VMware NSX-T Data Center. 14 Known Issues