Dell PowerStore 1200T EMC PowerStore Planning Guide - Page 12
Power requirements for the SAS expansion enclosure, Table 6. Power requirements
![]() |
View all Dell PowerStore 1200T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Power requirements for the SAS expansion enclosure Power requirements vary depending on system configuration, loading, and environmental conditions. The table below describes the maximum expected power draw. To estimate power consumption values for your specific environment, go to https:// powercalculator.dellemc.com/. Table 6. Power requirements Requirement AC line voltage AC line current (operating maximum) Description 100 to 240 VAC ± 10%, single-phase, 47 to 63 Hz 3.32 A max at 100 VAC Power consumption (operating maximum) Power factor Heat dissipation (operating maximum) In-rush current Startup surge current 1.66 A max at 200 VAC 308 VA (319 W) max at 100 VAC 332 VA (315 W) max at 200 VAC 0.95 minimum at full load, 100V/200V 1.11 x 106 J/hr. (1,088 Btu/hr.) max at 100 VAC 1.20 x 106 J/hr, (1,075 Btu/hr) max at 200 VAC 30 A max for 1/2 line cycle per line cord at 240 VAC 40 Amps peak max per line cord at any line voltage. AC protection AC inlet type Ride-through time Current sharing 15 A fuse on each power supply, both Line and Neutral IEC320-C14 appliance coupler, per power zone 12-millisecond minimum ± 5% of full load between power supplies Power requirements for the NVMe expansion enclosure Power requirements vary depending on system configuration, loading, and environmental conditions. The table below describes the maximum expected power draw. To estimate power consumption values for your specific environment, go to https:// powercalculator.dellemc.com/. Table 7. Power requirements Requirement AC line voltage Description 100 to 240 VAC +/- 10%, single-phase, 47 to 63 Hz AC line current (operating maximum) 10.06 A max at 100 VAC 5.0 A max at 200 VAC Power consumption (operating maximum) 1016 VA (965 W) max at 100 VAC 1006 VA (956 W) max at 200 VAC Power factor 0.95 minimum at full load 100V/200V Heat dissipation (operating maximum) 3.47 x 10 6 J/hr (3,293 Btu/hr) max at 100 VAC 3.44 x 10 6 J/hr (3,262 Btu/hr) max at 200 VAC In-rush current 82A max for 1/2 Line cycle per line cord at 200 VAC Startup surge current 100A Max for up to 125uSec AC protection 15 A fuse on each power supply, both Line and Neutral AC inlet type IEC320-C14 appliance coupler, per power zone 12 Site Planning
![](/manual_guide/products/dell-powerstore-1200t-emc-powerstore-planning-guide-dfb73b9/12.png)