Dell PowerStore 9000T EMC PowerStore Installation and Service Guide - Page 29
Verify the operation of a replacement drive, Return a faulted part
View all Dell PowerStore 9000T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Figure 22. Installing a 2.5" drive 5. If you are installing an NVMe NVRAM drive, push the latch cover into place. The activity light flashes to indicate that the spin-up sequence has begun. Verify the operation of a replacement drive Steps 1. From PowerStore Manager, select Hardware. 2. Select the enclosure where you replaced the faulted drive. 3. From the Hardware card, select the drive. The status of the replacement drive should read Healthy. If the status is still Faulted, wait a few minutes and refresh PowerStore Manager. If the status does not change, ensure that the drive is correctly seated, or contact your service provider. 4. Click Stop Blink LED. Return a faulted part About this task For US customers, return defective material within five business days. For International customers, return defective material within 10 business days. The materials required to return your defective part are supplied with the good part shipment. Base enclosure service procedures 29