Dell PowerStore 9000T EMC PowerStore Installation and Service Guide - Page 32

Verify the operation of a new part, Replace a power supply

Page 32 highlights

Figure 24. Installing a 2.5" drive 5. If you are installing an NVMe NVRAM drive, push the latch cover into place. The activity light flashes to indicate that the spin-up sequence has begun. Verify the operation of a new part Steps 1. From PowerStore Manager, select Hardware. 2. Select the appliance where you added the part. 3. From the Hardware card, select the view of the system where you added the part. The status of the part should read Healthy. If the status is Faulted, wait a few minutes and refresh PowerStore Manager. If the status does not change, ensure the part is correctly seated, or call support. Replace a power supply Take the following actions to remove the faulted power supply and install the replacement power supply into the system. 32 Base enclosure service procedures

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

Figure 24. Installing a 2.5" drive
5.
If you are installing an NVMe NVRAM drive, push the latch cover into place.
The activity light flashes to indicate that the spin-up sequence has begun.
Verify the operation of a new part
Steps
1.
From PowerStore Manager, select
Hardware
.
2.
Select the appliance where you added the part.
3.
From the
Hardware
card, select the view of the system where you added the part.
The status of the part should read
Healthy
. If the status is
Faulted
, wait a few minutes and refresh PowerStore Manager. If the
status does not change, ensure the part is correctly seated, or call support.
Replace a power supply
Take the following actions to remove the faulted power supply and install the replacement power supply into the system.