Dell PowerSwitch S4112F-ON Open Networking Hardware Diagnostic Guide April 201 - Page 55
nputool -i -t 1 -T ixia_self -d, DMA pool size: 16777216
View all Dell PowerSwitch S4112F-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
root@dell-diag-os:~# root@dell-diag-os:~# nputool -init -test 1 -traffic cpu_adj DMA pool size: 16777216 PCI unit 0: Dev 0x8375, Rev 0x11, Chip BCM88375_B0, Driver BCM88375_B0 sysconf_probe successful global_sal_config successful *** 1 BCM devices are detected Diag NPU initialization over Test link_status_test for NPU 0 SKIPPED
root@dell-diag-os:~#
root@dell-diag-os:~# nputool -init -test
1
-traffic
cpu_adj
DMA pool size: 16777216
PCI unit 0: Dev 0x8375, Rev 0x11, Chip BCM88375_B0, Driver BCM88375_B0
sysconf_probe successful
global_sal_config successful
***
1 BCM devices are detected
Diag NPU initialization over
Test link_status_test for NPU 0
.............
SKIPPED <<<---
Test snake_traffic_test for NPU 0
.............
Passed
Test prbs_mac_test for NPU 0
.............
SKIPPED <<<---
Test prbs_ext_test for NPU 0
.............
SKIPPED <<<---
Test uplink_link_status_test for NPU 0
.............
SKIPPED <<<---
Test uplink_snake_traffic_test for NPU 0
.............
SKIPPED <<<---
Test uplink_prbs_mac_test for NPU 0
.............
SKIPPED <<<---
Test uplink_prbs_ext_test for NPU 0
.............
SKIPPED <<<---
NPU tests
...........................................
Passed
root@dell-diag-os:~#
IXIA
traffic
with external loopback
Tests the
traffic
sent from IXIA to port-1 and to the front-end ports which are connected with external Loopback optics.
Connect the
first
port to IXIA and all other ports with QSFP28 Loopback optics.
•
nputool -i -t 1 -T ixia_self -d
•
nputool --init --test 1 --traffic ixia_self -d
These commands
configure
the virtual local area network (VLAN) and after the
BCM.0>
shell displays, send the
traffic
from IXIA. To verify
the counters, run the
show c
command in the BCM shell.
IXIA
traffic
with adjacent loopback
Tests the
traffic
sent from IXIA to the front-end ports which are connected with DACs or optics with cables connected top-to-bottom.
Connect the
first
two ports to IXIA and all the remaining ports with DACs or 40G/100G optics with cables.
•
nputool –i –t 1 –T ixia_adj
•
nputool --init --test 1 --traffic ixia_adj
The previous commands
configure
the VLAN and after the
BCM.0>
shell displays. To verify the counters, run the
show c
command in the
BCM shell.
CPU
traffic
with external loopback for uplink ports (SFP+)
Traffic
is sent from the CPU to the SFP+ ports.
Connect all the ports with the SFP+ optics with TX and RX shorted.
•
nputool -i -t 5 -T cpu_self
•
nputool --init --test 5 --traffic cpu_self
CPU
traffic
for uplink ports connected between adjacent ports
Traffic
is sent from the CPU internally generated packet to the front-end Dell EMC SFP+ ports which are connected with SFP+ optics
using a cable.
Connect the SFP+ ports with the Dell EMC SFP+ optics using cables.
•
nputool -i -t 5 -T cpu_adj
Dell EMC DAIG-OS tools