Dell PowerSwitch S4112F-ON Open Networking Hardware Diagnostic Guide April 201 - Page 86

updatetool, Tests, CLI optionsOutput

Page 86 highlights

Temperature Sensor 3 Passed Temperature Sensor 4 Passed Temperature Sensor 5 Passed Temperature Sensor 6 Passed Temperature Sensor 7 Passed Temperature Sensor 8 Passed Temperature Sensor 9 Passed Temp Sensors: Overall test results ----- >>> Passed root@dell-diag-os:/opt/dellemc/diag/bin# root@dell-diag-os:/opt/dellemc/diag/bin# temptool --show --lpc Temperature Sensor 1 temperature value is 30.3 C Temperature Sensor 2 temperature value is 23.1 C Temperature Sensor 3 temperature value is 22.2 C Temperature Sensor 4 temperature value is 26.0 C Temperature Sensor 5 temperature value is 21.8 C Temperature Sensor 6 temperature value is 22.0 C Temperature Sensor 7 temperature value is 23.5 C Temperature Sensor 8 temperature value is 31.0 C Temperature Sensor 9 temperature value is 42.0 C root@dell-diag-os:/opt/dellemc/diag/bin# updatetool The updatetool shows the CPLD, FPGA, BMC, and BIOS versions used to upgrade the CPLD, FPGA, BMC, and BIOS. NOTE: For older platforms, such as the S4100-ON Series, updatetool is not available. Instead use cpldupgradetool. Tests There are no defined tests with updatetool. CLI options Syntax: ./updatetool Print the Help-Text:= updatetool --h (or) updatetool -h Tool Version:= updatetool --version (or) updatetool -v Device function list:= updatetool --dev= [--index=IOM Slot] --list (or) updatetool -D [-i IOM Slot] -l Device Region:= updatetool --dev= --set_region= (or) updatetool -D -S updatetool --dev= --get_region (or) updatetool -D -G Device Version:= updatetool --dev= [--index=IOM Slot] --device_version (or) updatetool -D [-i IOM Slot] -V Update the Device:= updatetool --dev= [--index=IOM Slot] --update --file= (or) updatetool -D [-i IOM Slot] -U -e filename Read the Device:= updatetool --dev= [--index=IOM SLOT] --read -file= updatetool -D [-i IOM SLOT] -r -e filename Device Flash Info:= updatetool --dev= [--index=IOM SLOT] --flash_info updatetool -D [-i IOM SLOT] -F 86 Dell EMC DAIG-OS tools

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Temperature Sensor 3
.......................
Passed
Temperature Sensor 4
.......................
Passed
Temperature Sensor 5
.......................
Passed
Temperature Sensor 6
.......................
Passed
Temperature Sensor 7
.......................
Passed
Temperature Sensor 8
.......................
Passed
Temperature Sensor 9
.......................
Passed
Temp Sensors: Overall test results ----- >>> Passed
root@dell-diag-os:/opt/dellemc/diag/bin#
root@dell-diag-os:/opt/dellemc/diag/bin# temptool --show --lpc
Temperature Sensor 1 temperature value is 30.3 C
Temperature Sensor 2 temperature value is 23.1 C
Temperature Sensor 3 temperature value is 22.2 C
Temperature Sensor 4 temperature value is 26.0 C
Temperature Sensor 5 temperature value is 21.8 C
Temperature Sensor 6 temperature value is 22.0 C
Temperature Sensor 7 temperature value is 23.5 C
Temperature Sensor 8 temperature value is 31.0 C
Temperature Sensor 9 temperature value is 42.0 C
root@dell-diag-os:/opt/dellemc/diag/bin#
updatetool
The
updatetool
shows the CPLD, FPGA, BMC, and BIOS versions used to upgrade the CPLD, FPGA, BMC, and BIOS.
NOTE:
For older platforms, such as the S4100-ON Series,
updatetool
is not available. Instead use
cpldupgradetool
.
Tests
There are no
deļ¬ned
tests with
updatetool
.
CLI options
Syntax: ./updatetool <option>
Print the Help-Text:=
updatetool --h
(or)
updatetool -h
Tool Version:=
updatetool --version
(or)
updatetool -v
Device function list:=
updatetool --dev=<CPLD|FPGA|MAIN-BMC|BIOS|ALL> [--index=IOM Slot] --list (or)
updatetool -D <devname | ALL> [-i IOM Slot] -l
Device Region:=
updatetool --dev=<MAIN-BMC|BIOS> --set_region=<primary|backup> (or)
updatetool -D <devname> -S <region>
updatetool --dev=<BMC|BIOS> --get_region (or)
updatetool -D <devname> -G
Device Version:=
updatetool --dev=<CPLD|FPGA|MAIN-BMC|BIOS|ALL> [--index=IOM Slot] --device_version (or)
updatetool -D <devname | ALL> [-i IOM Slot] -V
Update the Device:=
updatetool --dev=<CPLD|FPGA|MAIN-BMC|BIOS> [--index=IOM Slot] --update --file=<filename> (or)
updatetool -D <devname> [-i IOM Slot] -U -e filename
Read the Device:=
updatetool --dev=<CPLD|FPGA|MAIN-BMC|BIOS> [--index=IOM SLOT] --read -file=<filename>
updatetool -D <devname> [-i IOM SLOT] -r -e filename
Device Flash Info:=
updatetool --dev=<CPLD|FPGA|MAIN-BMC|BIOS> [--index=IOM SLOT] --flash_info
updatetool -D <devname> [-i IOM SLOT] -F
86