Dell PowerVault 122T LTO Dell PowerVault 122T DLT VS80 Autoloader User's Guide - Page 33

Exporting Cartridges, Loading Cartridges, Unloading Cartridges

Page 33 highlights

2. From the Home screen or main menu, press + or - until Commands appears on the top line of the LCD screen. 3. Press Enter to access the available options. 4. Press + or - until Import appears on the LCD screen, and then press Enter. 5. Press + or - until the desired slot number appears on the LCD screen and press Enter. You are not given the option to import a cartridge to an occupied slot. 6. When Insert Cartridge Slot appears on the LCD screen and the media door opens, insert the desired data cartridge into the media door so that the write-protect switch is facing out from the autoloader and towards the right. NOTE: If you are using the Operator's Panel to clean the drive, import the cleaning cartridge only when the operator panel requests it. You may keep a cleaning cartridge in the autoloader if the backup software can manage the drive cleaning. 7. Repeat steps 5 and 6 as needed for any additional cartridges. 8. Press Cancel when you are done importing cartridges. 9. Verify that the LCD screen shows that the desired slots have cartridges installed. Importing a Cartridge Exporting Cartridges This option moves a cartridge from a specific slot to the media door. To export one or more cartridges from the autoloader, follow these steps: 1. From the Home screen or main menu, press + or - until Commands appears on the top line of the LCD screen, and then press Enter. 2. Press + or - until Export appears on the LCD screen, and then press Enter. 3. Press + or - until the desired slot number appears on the LCD screen, and then press Enter. You are not given the option to export from an empty slot. 4. When Remove Cartridge appears on the LCD screen and the cartridge is ejected through the media door, remove the exported cartridge from the autoloader, and then press Enter. 5. Repeat steps 3 and 4 as needed for any additional cartridges. 6. Press Cancel when you are finished exporting cartridges. 7. Make sure the LCD screen indicates that the desired slots contain cartridges. Exporting a Cartridge Loading Cartridges This option loads a cartridge from the autoloader carousel into the tape drive. To use this option, follow these steps: 1. From the Home screen or main menu, press + or - until Commands appears on the top line of the LCD screen, and then press Enter. 2. Press + or - until Load Cartridge appears on the LCD screen, and then press Enter. 3. Press + or - until the desired slot number appears on the LCD screen, and then press Enter. The slot number you select indicates the cartridge to be loaded into the tape drive. NOTE: Only slot numbers that contain cartridges are displayed. 4. Status messages will be displayed while the cartridge is loading. Drive Stopped will be displayed when the operation is complete. 5. Press Cancel when you are finished loading the cartridge. Unloading Cartridges This option unloads the cartridge from the tape drive into its original slot. To use this option, follow these steps: 1. From the Home screen or main menu, press + or - until Commands appears on the top line of the LCD screen, and then press Enter. 2. Press + or - until Unload Cartridge appears on the LCD screen. Press Enter to unload the cartridge from the tape drive.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39

2.
From the Home screen or main menu, press
+
or
-
until
Commands
appears on the top line of the LCD screen.
3.
Press
Enter
to access the available options.
4.
Press
+
or
-
until
Import
appears on the LCD screen, and then press
Enter
.
5.
Press
+
or
-
until the desired slot number appears on the LCD screen and press
Enter
. You are not given the option to import a cartridge to an occupied
slot.
6.
When
Insert Cartridge Slot
appears on the LCD screen and the media door opens, insert the desired data cartridge into the media door so that the
write-protect switch is facing out from the autoloader and towards the right.
7.
Repeat steps 5 and 6 as needed for any additional cartridges.
8.
Press
Cancel
when you are done importing cartridges.
9.
Verify that the LCD screen shows that the desired slots have cartridges installed.
Importing a Cartridge
Exporting Cartridges
This option moves a cartridge from a specific slot to the media door. To export one or more cartridges from the autoloader, follow these steps:
1.
From the Home screen or main menu, press
+
or
-
until
Commands
appears on the top line of the LCD screen, and then press
Enter
.
2.
Press
+
or
-
until
Export
appears on the LCD screen, and then press
Enter
.
3.
Press
+
or
-
until the desired slot number appears on the LCD screen, and then press
Enter
. You are not given the option to export from an empty slot.
4.
When
Remove Cartridge
appears on the LCD screen and the cartridge is ejected through the media door, remove the exported cartridge from the
autoloader, and then press
Enter
.
5.
Repeat steps 3 and 4 as needed for any additional cartridges.
6.
Press
Cancel
when you are finished exporting cartridges.
7.
Make sure the LCD screen indicates that the desired slots contain cartridges.
Exporting a Cartridge
Loading Cartridges
This option loads a cartridge from the autoloader carousel into the tape drive. To use this option, follow these steps:
1.
From the Home screen or main menu, press
+
or
-
until
Commands
appears on the top line of the LCD screen, and then press
Enter
.
2.
Press
+
or
-
until
Load Cartridge
appears on the LCD screen, and then press
Enter
.
3.
Press
+
or
-
until the desired slot number appears on the LCD screen, and then press
Enter
. The slot number you select indicates the cartridge to be
loaded into the tape drive.
4.
Status messages will be displayed while the cartridge is loading.
Drive Stopped
will be displayed when the operation is complete.
5.
Press
Cancel
when you are finished loading the cartridge.
Unloading Cartridges
This option unloads the cartridge from the tape drive into its original slot. To use this option, follow these steps:
1.
From the Home screen or main menu, press
+
or
-
until
Commands
appears on the top line of the LCD screen, and then press
Enter
.
2.
Press
+
or
-
until
Unload Cartridge
appears on the LCD screen. Press
Enter
to unload the cartridge from the tape drive.
NOTE:
If you are using the Operator's Panel to clean the drive, import the cleaning cartridge only when the operator panel requests it.
You may keep a cleaning cartridge in the autoloader if the backup software can manage the drive cleaning.
NOTE:
Only slot numbers that contain cartridges are displayed.