Dell PowerVault 50F Dell PowerVault 56F 16-Port Fibre Channel Switch Inst - Page 64
VC Encoded Address Mode: 0..1 [1]
View all Dell PowerVault 50F manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
. switch:admin> configure Configure... Fabric parameters (yes, y, no, n): [no] yes Domain: (1..239) [1] BB credit: (1..16) [16] R_A_TOV: (4000..120000) [10000] E_D_TOV: (1000..5000) [2000] Data field size: (256..2112) [2112] Non-SCSI Tachyon Mode: (0..1) [0] Disable Device Probing: (0..1) [0] Unicast-only Operation: (0..1) [0] VC Encoded Address Mode: (0..1) [1] Disable Translative Mode: (0..1) [1] Per-frame Route Priority: (0..1) [0] Virtual Channel parameters (yes, y, no, n): [no] yes VC Link Control: (0..1) [0] VC Class 2: (2..5) [2] VC Class 3: (2..5) [3] VC Multicast: (6..7) [7] VC Priority 2: (2..3) [2] VC Priority 3: (2..3) [2] VC Priority 4: (2..3) [2] VC Priority 5: (2..3) [2] VC Priority 6: (2..3) [3] VC Priority 7: (2..3) [3] Arbitrated Loop parameters (yes, y, no, n): [no] yes Send FAN frames?: (0..1) [1] System services (yes, y, no, n): [no] yes rstatd (on, off): [off] on rusersd (on, off): [off] on No changes. 4-8 Installation and Troubleshooting Guide