Dell S6000 Dell Networking Installation Guide - Page 37
Fans, Components, S6000 Fan module
View all Dell S6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
6 Fans The S6000 comes from the factory with two PSUs and three fan modules installed in the chassis (see Figure 6-1). The S6000 has SKUs that support the following configurations. Installation of the fans is done as part of the factory install based on SKU type. • AC PSU with fan airflow from I/O to PSU • AC PSU with fan airflow from PSU to I/O • DC PSU with fan airflow from I/O to PSU • DC PSU with fan airflow from PSU to I/O All fans and PSUs in a configuration must be in the same airflow direction. Should a mixed airflow configuration happen, the software notifies you of the invalid configuration. The S6000 supports three fan trays with airflow directions from the I/O to the utility or the utility to the I/O. Environmental factors can decrease the amount of time required between fan replacements. Check the environmental factors regularly. An increase in temperature and/or particulate matter in the air might affect performance (for example, new equipment installation). CAUTION: Check the fans at six-month intervals and replace them as necessary. Regularly monitor the speeds of the cooling fans in order to accurately determine replacement intervals. Components • S6000 Fan module • S6000 Fan module - Reverse flow Figure 6-1. S6000 Fan Modules and PSU 1 - PSU 0 2 - Fan Modules 0-2 3 - PSU 1 Fans | 37