Dell Z9264F-ON EMC PowerSwitch Installation Guide March 2022 - Page 24

Optics removal, Switch start-up, After switch placement, Switch replacement

Page 24 highlights

Optics removal Remove an optic by pushing the tab on the optic and sliding the optic from the port. When removing optics with direct attach cables (DACs) from the port, pull the release tab firmly and steadily. Before pulling the release tab, you may need to gently push the optic into the port to ensure that it is seated properly. Do not jerk or tug repeatedly on the tab. Switch start-up Supply power to the Z9264F-ON switch after it is mounted in a rack or cabinet. Dell Technologies recommends reinspecting your switch before starting it up. Verify the following: ● Optional: The equipment is properly secured to the rack and properly grounded. ● Optional: The equipment rack is properly mounted and grounded. ● The ambient temperature around the unit, which may be higher than the room temperature, is within the limits that are specified for the Z9264F-ON switch. For more information, see Specifications. ● There is sufficient airflow around the unit. ● The input circuits are correctly sized for the loads and that you use sufficient overcurrent protection devices. ● All protective covers are in place. CAUTION: Do not start up the switch if you did not install a fan module. NOTE: A US AC or DC power cable is included for powering up an AC or DC power supply. You must order all other power cables separately. NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the Z9264F-ON switch and components. Start up sequence When the switch starts up, the fans immediately come on at high speed. The fan speed slows as the switch continues to boot. After switch placement After you have securely installed and powered on the Z9264F-ON switch: ● If you are using Dell EMC software, see switch documentation at www.dell.com/support. ● If you need ONIE information, see ONIE documentation at www.onie.org. ● If you are using third-party software, see your third-party documentation. NOTE: If necessary, to upgrade your software or firmware images, go to the Drivers and Downloads page for your switch at www.dell.com/support. Switch replacement The following steps describe removing and replacing a switch. For further assistance when replacing a switch, contact your Dell EMC support representative. NOTE: ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the switch and accessories. After you remove the original packaging, place the switch and components on an anti-static surface. 1. Back up the switch configuration to your back-up computer or laptop TFTP server. copy running-config tftp://hostip/filepath To establish a console connection to the switch CLI, assign an IP address on the switch network. 24 Z9264F-ON switch installation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Optics removal
Remove an optic by pushing the tab on the optic and sliding the optic from the port.
When removing optics with direct attach cables (DACs) from the port, pull the release tab firmly and steadily. Before pulling
the release tab, you may need to gently push the optic into the port to ensure that it is seated properly. Do not jerk or tug
repeatedly on the tab.
Switch start-up
Supply power to the Z9264F-ON switch after it is mounted in a rack or cabinet.
Dell Technologies recommends reinspecting your switch before starting it up. Verify the following:
Optional: The equipment is properly secured to the rack and properly grounded.
Optional: The equipment rack is properly mounted and grounded.
The ambient temperature around the unit, which may be higher than the room temperature, is within the limits that are
specified for the Z9264F-ON switch. For more information, see
Specifications
.
There is sufficient airflow around the unit.
The input circuits are correctly sized for the loads and that you use sufficient overcurrent protection devices.
All protective covers are in place.
CAUTION:
Do not start up the switch if you did not install a fan module.
NOTE:
A US AC or DC power cable is included for powering up an AC or DC power supply. You must order all other power
cables separately.
NOTE:
ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap
when handling the Z9264F-ON switch and components.
Start up sequence
When the switch starts up, the fans immediately come on at high speed. The fan speed slows as the switch continues to boot.
After switch placement
After you have securely installed and powered on the Z9264F-ON switch:
If you are using Dell EMC software, see switch documentation at
www.dell.com/support
.
If you need ONIE information, see ONIE documentation at
www.onie.org
.
If you are using third-party software, see your third-party documentation.
NOTE:
If necessary, to upgrade your software or firmware images, go to the
Drivers and Downloads
page for your switch
at
www.dell.com/support
.
Switch replacement
The following steps describe removing and replacing a switch. For further assistance when replacing a switch, contact your Dell
EMC support representative.
NOTE:
ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground
strap when handling the switch and accessories. After you remove the original packaging, place the switch and components
on an anti-static surface.
1.
Back up the switch configuration to your back-up computer or laptop TFTP server.
copy running-config tftp://hostip/filepath
To establish a console connection to the switch CLI, assign an IP address on the switch network.
24
Z9264F-ON switch installation