Epson 4000 Service Manual - Page 185
Service Req. 0001002f
UPC - 010343848337
View all Epson 4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 185 highlights
EPSON Stylus Pro 4000 SERVICE REQ. 0001002D Error meaning: Cleaning Unit work life error Cause of trouble Pump counter (8P x 1000 = 8,000P) has reached its regulated value. Remedy Replace the Cleaning Unit and reset the Cleaning Unit work life counter. (Reset When Cleaning Unit Change (p423).) NOTE: Refer to Table 3-4 "Corrective Actions for Displayed Warnings (p.160)" about the Cleaning Unit components. SERVICE REQ. 0001002F Error meaning: 360 DPI writing time out error Explanation At ASIC reset, cannot restore position held before reset or carriage interference, etc. Remedy Recover by turning power OFF and back ON. SERVICE REQ. 00010030 Error meaning: Multi Sensor Failure Cause of trouble Multi Sensor is damaged Remedy 1. Check if the connection between the Multi Sensor and C511MAIN Board, and correct it if abnormal. 2. Replace the Multi Sensor (p270) Revision B SERVICE REQ. 00010031 Error meaning: ASF phase detection error Cause of trouble ASF home position cannot be detected even though Pump Motor turns at designated amount. ASF Phase Sensor is damaged. Remedy 1. Check if the ASF phase detection wheel rotates smoothly, and correct it if abnormal. 2. Replace the ASF Phase Sensor (p257) SERVICE REQ. 00010032 CHECK P O IN T This error is for clarification only and does not actually occur. Troubleshooting Troubleshooting Based on Panel Messages 185