Frigidaire FER641FS Installation Instructions - Page 4

Location, Of Your Dryer - dimensions

Page 4 highlights

LOCATION OF YOUR DRYER DO NOT INSTALL YOUR DRYER: 1 fn an area exposed to dripping water or outside weather conditions 2 In an area where it will come in contact with curtains, drapes, or anything that will obstruct the flow of combustion and ventilation air. 3 On carpet Floor MUST be solid with a maximum slope of 1 inch (254 cm) INSTALLATION tN RECESS OR CLOSET 1 A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors_ 2 No other fuel burning appliance shall be installed in the same closet as the Gas dryer 3 Your dryer needs the space around it for proper ventilation, DO NOT INSTALL YOUR DRYER IN A CLOSET WITH A SOLID DOOR. 4. A minimum of 120 square inches (7742 square era) of opening, equally divided at the top and bottom of the door, is required Air openings are required to be unobstructed when a door is installed_ A Iouvered door with equivalent air openings for the full length of the door is acceptable MINIMUM INSTALLATION CLEARANCES (inches) Alcove or Under counter FRONT 0(0cm) SIDES 0(0cm) REAR 0(0cm) TOP 15(38_1cm) Closet 1(254cm) 0(0cm) 0(0cm) 15(38_1cm) Closet door ventilation required; 2 Iouvered openings each 60 square inches (387 square centimeters) -- 3 inches (76 cm) from bottom and top of door. THIS DRYER MUST BE EXHAUSTED OUTDOORS, 5, The following illustrations show minimum clearance dimensions for propel operation in a recess or closet installation it CLOSET DOOR II --_ii_ NOTE: Under counter and stack models- 0 inches (0 cm) for sides, rear, and top. 0" (0 era) UNDER COUNTER INSTALLATION If an under counter* installation is desired, the dryer MUST have a top sheet kit installed, P/N 131629100. Kit is available from an authorized parts distributor. *Custom-sized countertop is required. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

LOCATION
OF YOUR DRYER
DO NOT
INSTALL
YOUR DRYER:
1
fn an area exposed to dripping water or outside weather conditions
2
In an area where
it will come in contact with
curtains, drapes, or
anything that will obstruct the flow
of combustion
and ventilation
air.
3
On carpet
Floor
MUST
be solid with
a maximum
slope of 1 inch
(254
cm)
INSTALLATION
tN
RECESS
OR CLOSET
1
A dryer
installed
in a bedroom,
bathroom,
recess or closet,
MUST
be exhausted
outdoors_
2
No
other
fuel
burning
appliance
shall
be
installed
in
the
same
closet
as the
Gas dryer
3
Your
dryer
needs the
space
around
it for
proper
ventilation,
DO
NOT
INSTALL
YOUR
DRYER
IN
A
CLOSET
WITH
A
SOLID
DOOR.
4.
A minimum
of 120 square inches (7742
square era) of opening,
equally divided at the top and bottom
of the door, is required
Air openings are required to be unobstructed
when
a door is
installed_ A Iouvered door with
equivalent
air openings for the
full length of the door is acceptable
MINIMUM
INSTALLATION
CLEARANCES (inches)
FRONT
SIDES
REAR
TOP
Alcove
or
Under
counter
0(0cm)
0(0cm)
0(0cm)
15(38_1cm)
Closet
1(254cm)
0(0cm)
0(0cm)
15(38_1cm)
Closet door ventilation
required; 2 Iouvered openings
each 60
square inches (387 square centimeters)
--
3 inches (76
cm)
from
bottom
and top of door.
THIS
DRYER
MUST
BE EXHAUSTED
OUTDOORS,
5,
The following
illustrations show minimum clearance dimensions
for propel operation
in a recess or closet installation
it
CLOSET
DOOR
NOTE:
for sides, rear, and top.
II
--_ii_
0"
(0
era)
Under counter and stack models-
0 inches (0 cm)
UNDER COUNTER INSTALLATION
If an under counter*
installation is desired, the dryer MUST have a top sheet kit
installed, P/N 131629100. Kit is available from an authorized parts distributor.
*Custom-sized countertop is required.
4