Fujitsu MAJ3364MP Manual/User Guide - Page 109
Maintenance requirements, See 3 Service life,
View all Fujitsu MAJ3364MP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
CAUTION 1. Always ground yourself with a wrist strap connected to ground before handling. ESD (Electrostatics Discharge) may cause the damage to the device. 2. To prevent electrical damage to the disk drive, turn the power off before mounting or removing a PCA or connecting or disconnecting a cable, connector, or plug. 3. Do not turn the power on while removing a PCA. This operation is required to prevent unexpected or unpredictable operation. 4. Do not use a conductive cleaner to clean a disk drive assembly. 5. Open all ventilation holes to prevent overheating of electric circuits. 6. Ribbon cables are marked with a colored line. Connect the ribbon cable to a cable connector with the colored wire connected to pin 1. 6.2.2 Maintenance requirements (1) Preventive maintenance Preventive maintenance such as replacing air filters is not required. CAUTION Damage Do not open the DE in the field because it is completely sealed. (2) Service life See "(3) Service life," in Section 2.1.5. 6 - 6 C141-E103-02EN