Safety Instructions Operating Instructions GEAppliances.com Problem The air is not always cool or hot during operation Possible Causes The heat pump is not producing hot air. The Smart Fan Auxiliary Controls may be set to continuous fan. What To Do • This is normal. The heat pump will produce warm air but not as hot as air produced when the higher-cost electric heat is used. • This causes the fan to blow room temperature air even when the compressor or heater cycles off. The continuous air movement provides better overall temperature control in the cool mode. See smart fan - Cooling/Heating on page 5. The air does not feel warm enough during heating operation The heat pump alone produces air that feels cooler than desired. • Use the Electric Heat Option. This turns off the heat pump and warms with electric heat only. NOTE: use of this option will result in increased energy consumption. The unit is not blowing out air The Smart Fan Auxiliary • See smart fan - Cooling/Heating on page 5. Controls may be set to cycle. The electric heating The power cord is not feature does not work firmly attached. • Remove the room cabinet and make sure that the yellow connector on the end of the power cord is firmly engaged. Temperature display flashes The compressor may have failed. • Set the operation control to STOP and then restart the unit. If the flashing light reappears within 30 minutes, call for service. Care and Cleaning Troubleshooting Tips Consumer Support 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

Problem
Possible Causes
What To Do
The air is not always
The heat pump is not
This is normal. The heat pump will produce warm air
cool or hot during
producing hot air.
but not as hot as air produced when the higher-cost
operation
electric heat is used.
The Smart Fan Auxiliary
This causes the fan to blow room temperature air
Controls may be set to
even when the compressor or heater cycles off.
continuous fan.
The continuous air movement provides better
overall temperature control in the cool mode.
See
Smart fan – Cooling/Heating
on page 5.
The air does not feel
The heat pump alone
Use the Electric Heat Option. This turns off the
warm enough during
produces air that feels
heat pump and warms with electric heat only.
heating operation
cooler than desired.
NOTE:
Use oF this option will result in increased energy
consumption.
The unit is not
The Smart Fan Auxiliary
See
Smart fan – Cooling/Heating
on page 5.
blowing out air
Controls may be set to cycle.
The electric heating
The power cord is not
Remove the room cabinet and make sure that the
feature does not work
firmly attached.
yellow connector on the end of the power cord is
firmly engaged.
Temperature display
The compressor may
Set the operation control to
STOP
and then restart
flashes
have failed.
the unit. If the flashing light reappears within
30 minutes, call for service.