GE AZ41E12DAB Owners Manual - Page 5
Auxiliary controls on your Zoneline.
View all GE AZ41E12DAB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Safety Instructions Operating Instructions Auxiliary controls on your Zoneline. Auxiliary Controls-Aux Set Button The auxiliary set controls are located behind the room cabinet, below the control panel. Remove the room cabinet. See the to Remove the Room Cabinet section. The owner is responsible for ensuring the auxiliary controls are set to the desired function. There are 9 different modes that can be set using the auxiliary set button. To change modes, press AUX SET ("AU" appears on the display). Press the mode button on the control pad until the first digit in the display shows the number corresponding to the mode you are choosing and the correct HEAT/COOL LED is lit. Press the up or down arrow (shown in the second digit of the display) to make the mode setting selection where applicable. Press the AUX SET button to confirm the selection. MODE 1 Smart Fan-Cooling/Heating The default setting for Mode 1 is as follows: Cooling: Continuous (ON) Heating: Cycle (OFF) Press MODE until a 1 appears in the first digit of the display for Smart Fan cool mode. The COOL LED light on the main control will be on. To change to heat mode, press MODE again. The HEAT LED light on the main control will be lit. Press the down arrow to set the indoor fan to cycle on/off when the unit is heating or cooling " ." Press the up arrow to set the indoor fan to run continuously " ." This is shown in the second digit of the display. Press AUX SET to confirm your selection and exit AUX SET mode, or press MODE to continue setting other functions. *Note: In cyclic cooling mode, the indoor fan will activate occasionally to verify airtemperature in the room. In cyclic heating mode, the fan will continue to operate for 90seconds after the heating function has stopped in order to increase unit efficiency. GEAppliances.com Auxiliary Set Button Access Cover 8 HIGH LOW AUTO Cooling - Cycle* HIGH LOW AUTO Cooling - Continuous HIGH LOW AUTO Heating - Cycle* HIGH LOW AUTO Heating - Continuous COOL FAN HEAT COOL FAN HEAT COOL FAN HEAT COOL FAN HEAT Care and Cleaning Troubleshooting Tips Consumer Support MODE 2 Load Shedding (Central Desk Control) The default setting for Mode 2 is OFF. This feature is active only if the unit is connected to a CDC and the CDC has control. Press MODE until a 2 appears in the first digit of the display for Load Shedding mode. Press the down arrow for OFF " " or the up arrow for ON " ." This is shown in the second digit of the display. When this mode is on, only the indoor fan can be turned ON or OFF with the unit controls. When this mode is off, all operation is disabled except Heat/Freeze Sentinel (Mode 3). Press AUX SET to confirm your selection and exit AUX SET mode, or press MODE to continue setting other functions. Load Shedding OFF Load Shedding ON 5