GE AZ41E12DAB Owners Manual - Page 4

Other features of your Zoneline.

Page 4 highlights

Safety Instructions Operating Instructions Other features of your Zoneline. Ventilation Control NOTE: two shipping screws must be removed from the vent door before use. see the installation instructions in the back of this manual. if you do not plan to use the ventilation feature, leave these two screws in place. The ventilation control lever is located at the middle left side of the Zoneline unit, behind the room cabinet. When set at the closed position, only the air inside the room is circulated and filtered. When set at the open position, some outdoor air will be drawn into the room. This will reduce the heating or cooling efficiency. Energy Tip: Keep the vent control in the closed position. The room air will be filtered and circulated. Open position Vent control (shown in middle position) Closed position Remove two shipping screws (if operation is desired) To Remove the Room Cabinet Additional controls are located behind the room cabinet. To remove: Pull out at the bottom to release it from the tabs (1). Then lift up (2). To replace: Place the tabs over the top rail (1). Push inward at the bottom until it snaps into place (2). Care and Cleaning Troubleshooting Tips Consumer Support Air Direction To change the air direction, remove the room cabinet. Remove the 7 louver screws that hold the louver insert in place. Flip the louver insert 180°, replace the screws and the room cabinet. Louver screws Remove the room cabinet and flip the louver insert to change the air direction. 4 Louver screws Default position

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

Consumer Support
Troubleshooting Tips
Care and Cleaning
Operating Instructions
Safety Instructions
Ventilation Control
NOTE:
Two shipping screws must be removed
From the vent door beFore use. See the Installation
Instructions in the back oF this manual. IF you do not
plan to use the ventilation Feature, leave these two
screws in place.
The ventilation control lever is located at
the middle left side of the Zoneline unit,
behind the room cabinet.
When set at the closed position, only the air
inside the room is circulated and filtered.
When set at the open position, some outdoor
air will be drawn into the room. This will reduce
the heating or cooling efficiency.
Energy Tip:
Keep the vent control in the closed
position. The room air will be filtered and circulated.
Air Direction
To change the air direction, remove the room
cabinet. Remove the 7 louver screws that hold
the louver insert in place. Flip the louver insert 180°,
replace the screws and the room cabinet.
Remove the room cabinet and flip the louver
insert to change the air direction.
4
Other features of your Zoneline.
To Remove the Room Cabinet
Additional controls are located behind the
room cabinet.
To remove:
Pull out at the bottom to release it from
the tabs (1). Then lift up (2).
To replace:
Place the tabs over the top rail (1). Push
inward at the bottom until it snaps into place (2).
Vent control
(shown in
middle position)
Open
position
Closed
position
Louver screws
Louver screws
Default
position
Remove two
shipping screws
(if operation is
desired)