GE AZ41E12DAB Owners Manual - Page 7
Caution - model
View all GE AZ41E12DAB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Safety Instructions GEAppliances.com Operating Instructions MODE 7 Duct Mode The default setting for Mode 7 is OFF. This setting is used when the unit is installed using a duct adapter kit. If the unit is ducted, the Duct Mode needs to be set to ON. This increases the fan speed to ensure proper circulation. Press MODE until a 7 appears in the first digit of the display. Press the up or down arrow keys to set this switch to OFF " " or ON " ." This is shown in the second digit of the display. Press AUX SET to confirm your selection and exit AUX SET mode. For Model AZ6100, press MODE to continue setting other functions. Pressing MODE on Model AZ4100 will return you to AUX SET mode and an "AU" will appear in the display. Duct Mode OFF Duct Mode ON MODE 8 All-Electric Heat (AZ6100 only) The default setting for Mode 8 is OFF. This electric heat option functions only on the 6100 model. When this option is ON " ," heat pump operation is locked out, causing the unit to provide only electric resistance heat. To set All-Electric Heat option, press MODE until an 8 appears in the first digit of the display. Press the up or down arrow keys to set this switch to OFF " " or ON " ." This is shown in the second digit of the display. Press AUX SET to confirm your selection and exit AUX SET mode, or press MODE to continue setting other functions. All-Electric Heat OFF All-Electric Heat ON Care and Cleaning MODE 9 Heat Boost (AZ6100 only) The default setting for Mode 9 is OFF. When Heat Boost is ON and outer temperatures are between 25ºF and 46ºF, heat pump only operation is locked out. This setting is used to provide supplementary heat to the heat pump operation by electric resistance heat in conditions where the heat pump-only operation is not sufficient to maintain a consistent, comfortable room temperature. NOTE: Temperature Boost option should not be used with remote thermostat operation. This will cause the unit to switch to resistance heat when the outdoor temperature is 46ºF. To set Heat Boost, press MODE until a 9 appears in the first digit of the display. Press the up or down arrow keys to set this switch to OFF " " or ON " ." This is shown in the second digit of the display. Press AUX SET to confirm your selection and exit AUX SET mode. Heat Boost OFF Heat Boost ON Troubleshooting Tips Auxiliary Controls-Terminal Connections The auxiliary controls are located behind the room cabinet beneath the access cover. 1 Turn off and unplug the unit. 2 Remove the room cabinet. See the to Remove the Room Cabinet section. 3 Remove the screw from the access cover. 4 To make wiring connections, insert the wires into the bottom of the terminals and tighten screws securely. 5 After all desired connections have been made, replace the access cover and room cabinet. The owner is responsible for making all connections and setting the appropriate AUX SET mode. CAUTION: Improper wiring may damage the Zoneline electronics. No common busing is permitted. Damage or erratic operation may result. A separate wire pair must be run from each separate controlling switch to each individual Zoneline. EXT FAN CDC 24 VAC R FAN LO G FAN HI G REV VAL B COMP Y AUX HEAT W COMMON C Access Cover External Fan Central Desk Control Common White - Heater Yellow - Compressor Black - Solenoid (AZ61 only) Green - High Speed Fan Green - Low Speed Fan 7 Red - 24 V AC only Consumer Support