Page 9 highlights

Installation Instructions 15 4-WIRE POWER CORD INSTALLATION WARNING: The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. The ground lead must be connected to the frame of the range with the ground plate and the ground screw. A Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them. B Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS. C Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate and into the frame of the range. D Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/ neutral) is connected to the center lower position of the terminal block. Tighten screws securely into the terminal block. Before Terminal block Ground strap After Terminal block Ground strap or Neutral terminal Ground plate (grounding to range) Ground screw E Skip to Step 18 and proceed with the installation. 16 3-WIRE CONDUIT INSTALLATION A Loosen the 3 lower terminal screws from the terminal block. Insert the center bare wire (white/neutral) tip through the bottom center terminal block opening. On certain models, the wire will need to be inserted through the ground strap opening and then into the bottom center block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not overtighten the screws since it could damage the wires. NOTE: ALUMINUM WIRING: Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make connection. Connect wires according to this Step 16 or Step 17 depending on number of wires. Terminal block Wire tips Bracket Conduit Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes. B Skip to Step 18 and proceed with the installation. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

9
Installation Instructions
3-WIRE CONDUIT INSTALLATION
Loosen the 3 lower terminal screws
from the terminal block. Insert the center
bare wire (white/neutral) tip through the
bottom center terminal block opening.
On certain models, the wire will need
to be inserted through the ground strap
opening and then into the bottom center
block opening. Insert the two side bare
wire tips into the lower left and the lower
right terminal block openings. Tighten
the screws until the wire is firmly
secured (35 to 50 inch-lbs.). Do not over-
tighten the screws since it could damage
the wires.
NOTE: ALUMINUM WIRING:
Aluminum building wire may be used
but it must be rated for the correct
amperage and voltage to make
connection. Connect wires according
to this Step 16 or Step 17 depending
on number of wires.
Wire used, location and enclosure of
splices, etc., must conform to good
wiring practices and local codes.
Skip to Step 18 and proceed with the
installation.
B
A
16
4-WIRE POWER CORD
INSTALLATION
WARNING:
The neutral wire of
the supply circuit must be connected to
the neutral terminal located in the lower
center of the terminal block. The power
leads must be connected to the lower
left and the lower right terminals of the
terminal block. The ground lead must be
connected to the frame of the range
with the ground plate and the ground
screw.
Remove the 3 lower terminal screws
from the terminal block. Remove the
ground screw and ground plate and
retain them.
Cut and discard the ground strap.
DO NOT DISCARD ANY SCREWS.
Insert the one ground screw into the
power cord ground wire terminal ring,
through the ground plate and into the
frame of the range.
Insert the 3 terminal screws (removed
earlier) through each power cord
terminal ring and into the lower
terminals of the terminal block. Be
certain that the center wire (white/
neutral) is connected to the center lower
position of the terminal block. Tighten
screws securely into the terminal block.
Skip to Step 18 and proceed with the
installation.
E
D
C
B
A
15
or
Terminal
block
Ground strap
Ground
strap
Neutral
terminal
Before
After
Terminal
block
Ground
screw
Ground
plate
(grounding
to range)
Bracket
Conduit
Wire tips