GE PDW7900P Installation Instructions - Page 4
Prepare Electrical Wiring
View all GE PDW7900P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Installation Preparation PREPARE ELECTRICAL WIRING FORPERSONALSAFETVI _Ji bReefomroevebehgoiunsneingfuseinsotarlloaptieonn. circDuoitnotbreuaskeer this appliance, an extension cord or adapter plug with Electrical Requirements • This appliance must be supplied with 120V, 60Hz.. and connected to on individual properlg grounded branch circuit. protected bg a 15 or 20 ampere circuit breaker or time delay fuse. o Wiring must be 2 wire with ground and rated for 75°C {176%}. • If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding. Grounding Instructions-Cable Direct This appliance must be connected to a grounded metal, permanent wiring sgstem, or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal or lead on the appliance. Grounding Instructions-Power Cord Models This appliance must be grounded. In tile event of o malfunction or breakdown, grounding will reduce the risk of electric shock bg providing a path of least resistance for electric current. This appliance is equipped with o cord having an equipment grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with at! local codes end ordinances. The improper connection of the equipment grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if gou are in doubt that the appliance is propertg grounded. " '! Receptacle : ", 8. / ' Location --r-k ",, I 8 '',i:lli Hole(Max,} \ t]--- _,-F_ ! _: 3'from :':::: C a,b'i,ne t Figure E /Receptacle from Wakkx_x_k V Location Area Ground-_' i Black-" VVhite For models equipped with power cord: Do not modifg the plug provided with the appliance; if it will not fit the outlet hove a proper outlet installed by a qualified technician. Cabinet Preparation and Wire Routing • The wiring meg enter the opening from efther side, rear or the floor within the shaded area. ° Cut o 1-t/2" maximum diameter hole to admit the electrical cable. Cable direct connections meg pass through the same hole as the drain hose and hot water line, if convenient. If cabinet wal! is metal, the hole edge must be €overed With a bushing. Note: Power cords with plug must pass through a separate hole. Electrical Connection to Dishwasher Electrical connection is on the right front of dishwasher. • For cable direct connections the cable must be routed as shown in Figure E Cable must extend a minimum of 24" from the rear wall. ° For power cord connections, install a 3-prong grounding tgpe receptacle in the sink cabinet rear wall. 6" min, or !8" max. from the opening, 6" to 18" above the floor. ..... --iii //