Genie ScrewDrive Owner's Manual - Page 31
Troubleshooting, Sect 10-maintenance & Troubleshooting
View all Genie ScrewDrive manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
SECT 10-MAINTENANCE & TROUBLESHOOTING MONTHLY MAINTENANCE MAINTENANCE CHECK-OFF Door springs and hardware. • Oil door rollers, bearings, and hinges. - Use silicone lubricant or light oil. YEAR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 NOTE: Do not operate door automatically or manually if springs are broken. CONTACT A PROFESSIONAL FOR SERVICE. MONTH 31 J J JJJ JJJJJ J JJJJJ JJJJ Balance door. • Close door. • Release carriage from rail assembly. - Pull emergency release knob down. • Raise door manually about 3 feet. - Door should stay in that position. F F FFF FFFFF F FFFFF FFFF M M MMM MMMMM M MMMMM MMMM A A AAA AAAAA A AAAAA AAAA M M MMM MMMMM M MMMMM MMMM NOTE: If door moves, HAVE DOOR SERVICED BY A PROFESSIONAL. • Reattach carriage to rail assembly. - Pull emergency release knob toward power head. • Close door J J JJJ JJJJJ J JJJJJ JJJJ J J JJJ JJJJJ J JJJJJ JJJJ A A AAA AAAAA A AAAAA AAAA Contact reverse. • Lay 2" x 4" board flat on the floor in the center of garage doorway (See page 28). • Close door using wall button or remote control. NOTE: If door fails to reverse on contact with board. See page 28, CONTACT REVERSE. If operator still fails, replace operator or HAVE THE OPERATOR SERVICED BY A PROFESSIONAL. YEARLY MAINTENANCE S S SSS SSSSS S SSSSS SSSS O O OOO OOOOO O OOOOO OOOO N N NNN NNNNN N NNNNN NNNN D D DDD DDDDD D DDDDD DDDD Just mark the appropriate box each time you perform routine maintenance. Drive Screw • Lubricate drive screw. - Use GENIE GLU3 lubricant. One less thing you will have to try and remember on your busy schedule is whether or not you did the maintenance last month. CAUTION Use only GENIE GLU3 lubricant, because other lubricants may damage operator. TROUBLESHOOTING FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM STB SELF-DIAGNOSTIC TROUBLESHOOTING SOURCE (RED LED) SENSOR (GREEN LED) INDICATED CONDITION REQUIRED ACTION ON ON NORMAL OPERATION NONE REQUIRED OFF OFF 1.POWER HEAD NOT POWERED 2.WIRING FROM POWER HEAD BAD 1.CHECK BREAKERS, FUSES, PLUGS 2.CHECK WIRING FOR OBVIOUS SHORTS OFF ON 1.WIRING TO SOURCE MISSING OR BAD 2.POWER HAS BEEN INTERRUPTED 1.CHECK WIRING 2.REMOVE POWER AND REAPPLY 2 BLINKS, PAUSE (REPEAT) ON 1.BEAM NOT ALIGNED 2. BEAM OBSTRUCTED 3.SENSOR DEFECTIVE 1.CHECK ALIGNMENT 2. CHECK FOR OBSTRUCTION 3.CALL CUSTOMER SERVICE 2 BLINKS, PAUSE (REPEAT) OFF 1.WIRE TO SENSOR MISSING OR BAD 2.SENSOR DEFECTIVE 1.CHECK WIRING 2.CALL CUSTOMER SERVICE 3 BLINKS, PAUSE (REPEAT) ON 1.SENSOR RECEIVING INTERFERENCE 1.ATTEMPT TO DETERMINE SOURCE OF INTERFERENCE 2.CALL CUSTOMER SERVICE 4 BLINKS, PAUSE (REPEAT) ON 1.SOURCE NOT SENDING PULSES 2.SOURCE DEFECTIVE 1.CALL CUSTOMER SERVICE 2.CALL CUSTOMER SERVICE NOTE: IF OPERATING PROBLEM EXISTS, THE DOOR CAN BE CLOSED IF YOU: 1. DISCONNECT THE STB SYSTEM FROM THE OPERATOR AND 2. HOLD WALL CONTROL BUTTON DOWN UNTIL DOOR IS CLOSED. (REMOTE CONTROL & WIRELESS KEYPAD WILL NOT WORK WITHOUT STB) CUSTOMER SERVICE: 1.800.354.3643 or www.geniecompany.com