power the equipment during a time cycle when the TriStar VS pump is operating at an appropriate flow rate to operate the other equipment, as defined by the timers set in the Timer Menu. See section 6.7 4.10. Remote Control Wiring/Operation TriStar VS can be controlled in a wide variety of ways as described below: 1. TriStar VS (SP3200VSP) can operate by itself in Stand-Alone Mode using its built-in programmable timers. 2. TriStar VS (SP3200VSP) can also be controlled from third party controls (i.e. another manufacturer's control) and Hayward controls that are not software compatible using relay contacts. See section 5.3 for more information regarding connecting TriStar VS and third party/non-software compatible Hayward controls. 3. TriStar VS (SP3200VSPND) can communicate with and be controlled by Hayward Pro Logic. See section 5.4 for more information regarding connecting TriStar VS and Hayward Pro Logic. 4.11. Digital Control Interface Orientation The Digital Control Interface can be rotated to any of four desired positions after installation by removing the two screws securing the interface to the motor drive, lifting the interface and rotating it to the desired position, and replacing the two screws in the new position. (Figure 4.11-1) Figure 4.11-1 Page 11 of 36 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar VS Pump IS3200VSP Rev-C

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 11 of 36
TriStar VS Pump
IS3200VSP
Rev-C
power the equipment during a time cycle when the TriStar VS pump is operating at an appropriate flow rate to
operate the other equipment, as defined by the timers set in the Timer Menu. See section 6.7
4.10.
Remote Control Wiring/Operation
TriStar VS can be controlled in a wide variety of ways as described below:
1.
TriStar VS (SP3200VSP) can operate by itself in Stand-Alone Mode using its built-in programmable timers.
2.
TriStar VS (SP3200VSP) can also be controlled from third party controls (i.e. another manufacturer’s control) and
Hayward controls that are not software compatible using relay contacts. See section 5.3 for more information
regarding connecting TriStar VS and third party/non-software compatible Hayward controls.
3.
TriStar VS (SP3200VSPND) can communicate with and be controlled by Hayward Pro Logic. See section 5.4 for
more information regarding connecting TriStar VS and Hayward Pro Logic.
4.11.
Digital Control Interface Orientation
The Digital Control Interface can be rotated to any of four desired positions after installation by removing the two
screws securing the interface to the motor drive, lifting the interface and rotating it to the desired position, and
replacing the two screws in the new position. (
Figure 4.11-1
)
Figure 4.11-1