Figure 4.12-4: Wall Mounting the Interface 4.13. Installation Procedure Please review sections 4.1 through 4.12 before continuing with this section. 1. TURN OFF THE ELECTRICAL POWER AT THE CIRCUIT BREAKER. 2. Remove the two screws securing the interface to the motor drive. 3. Disconnect the short cable that extends out from the motor drive to the interface. 4. Loosen the three screws securing the interface mounting plate to the motor drive and remove the interface mounting plate to gain access to the drive wiring compartment. 5. Disconnect the short cable on the interface mounting plate from the RS485 terminal block on the drive PCB. 6. Connect 230VAC line power supply wiring to the terminals and ground screw as shown in the Input Power Wiring diagram. Wiring must be routed through the right side conduit opening. See section 5.1 for diagram. 7. If the pump will be controlled using a Hayward Pro Logic control (SP3200VSPND only), connect a two-conductor cable as shown in the Hayward Pro Logic Control Wiring diagram. See section 5.4. 8. If the pump will be controlled using relay contacts from an external control (SP3200VSP only), connect the digital input terminals to the relay contacts as shown in the External Relay Speed Control Wiring diagram. See section 5.3. 9. If the installation will use the remote stop feature of the drive, connect the digital input terminals to the remote stop switch as shown in the Remote Stop Wiring diagram. See section 5.5. 10. Wiring for remote control and/or remote stop functions must be routed through the left side conduit opening. Use a multi-conductor, jacketed cable suitable for the installation location. Use a liquid tight cordgrip, appropriately sized for the cable being used, to seal the left side conduit opening. 11. Connect the pump to the pool bonding system using 8AWG (6AWG for Canada) wire. A lug for bonding is provided on the outside of the drive enclosure. 12. Reconnect the short cable on the interface mounting plate to the RS485 terminal block on the drive PCB. 13. After all electrical connections have been made, replace the interface mounting plate, taking care to make sure it is properly aligned with the motor drive, and tighten the three screws to secure. 14. Reconnect the short cable that extends out from the motor drive to the interface. 15. Mount the interface to the interface mounting plate in the desired orientation. Page 14 of 36 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TriStar VS Pump IS3200VSP Rev-C

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 14 of 36
TriStar VS Pump
IS3200VSP
Rev-C
Figure 4.12-4: Wall Mounting the Interface
4.13.
Installation Procedure
Please review sections 4.1 through 4.12 before continuing with this section.
1.
TURN OFF THE ELECTRICAL POWER AT THE CIRCUIT BREAKER.
2.
Remove the two screws securing the interface to the motor drive.
3.
Disconnect the short cable that extends out from the motor drive to the interface.
4.
Loosen the three screws securing the interface mounting plate to the motor drive and remove the interface
mounting plate to gain access to the drive wiring compartment.
5.
Disconnect the short cable on the interface mounting plate from the RS485 terminal block on the drive PCB.
6.
Connect 230VAC line power supply wiring to the terminals and ground screw as shown in the Input Power Wiring
diagram.
Wiring must be routed through the right side conduit opening. See section 5.1 for diagram.
7.
If the pump will be controlled using a Hayward Pro Logic control (SP3200VSPND only), connect a two-conductor
cable as shown in the Hayward Pro Logic Control Wiring diagram.
See section 5.4.
8.
If the pump will be controlled using relay contacts from an external control (SP3200VSP only), connect the
digital input terminals to the relay contacts as shown in the External Relay Speed Control Wiring diagram.
See
section 5.3.
9.
If the installation will use the remote stop feature of the drive, connect the digital input terminals to the remote
stop switch as shown in the Remote Stop Wiring diagram.
See section 5.5.
10.
Wiring for remote control and/or remote stop functions must be routed through the left side conduit opening.
Use a multi-conductor, jacketed cable suitable for the installation location. Use a liquid tight cordgrip,
appropriately sized for the cable being used, to seal the left side conduit opening.
11.
Connect the pump to the pool bonding system using 8AWG (6AWG for Canada) wire.
A lug for bonding is
provided on the outside of the drive enclosure.
12.
Reconnect the short cable on the interface mounting plate to the RS485 terminal block on the drive PCB.
13.
After all electrical connections have been made, replace the interface mounting plate, taking care to make sure it
is properly aligned with the motor drive, and tighten the three screws to secure.
14.
Reconnect the short cable that extends out from the motor drive to the interface.
15.
Mount the interface to the interface mounting plate in the desired orientation.