Hayward Universal H-Series Low NOx Service/Installation: H150FDN H200FDN H25 - Page 17

Table 7, Vent Pipe & Terminal Specifications for Positive-Pressure Indoor Vent Kits

Page 17 highlights

17 Table 7 Vent Pipe & Terminal Specifications for Positive-Pressure Indoor Vent Kits Kit Part Number UHXPOSHZ11501 UHXPOSHZ12001 UHXPOSHZ12501 UHXPOSHZ13001 UHXPOSHZ13501 UHXPOSHZ14001 Heater Model H150FD H200FD H250FD H300FD H350FD H400FD Nominal Vent Pipe Diameter 6 inch 6 inch 8 inch Vent Type Single-Wall Double-Wall Single-Wall Double-Wall Single-Wall Double-Wall Vent Pipe Heatfab Saf-T Vent EZ Seal P/N 960x * Heatfab SafT Vent CI Plus P/N CCA06Lxx ** Heatfab Saf-T Vent EZ Seal P/N 960x * Heatfab SafT Vent CI Plus P/N CCA06Lxx ** Heatfab Saf-T Vent EZ Seal P/N 980x * Heatfab Saf-T Vent CI Plus P/N CCA08Lxx ** Horizontal Vent Terminal Heatfab P/N 9614TERM (elbow terminal) and 5691CI (wall penetration) Heatfab P/N 9614TERM (elbow terminal), CCK06FC (collar), CCA06ADSV (connector ring), and CCL06WPNS (wall penetration) Heatfab P/N 5690CI Heatfab P/N CCE06WP Heatfab P/N 5890CI Heatfab P/N CCE08WP Vertical Vent Terminal Heatfab P/N 5600CI Heatfab P/N CCA06RC Heatfab P/N 5600CI Heatfab P/N CCA06RC Heatfab P/N 5800CI Heatfab P/N CCA08RC * For vent pipe section length, "x" should be: 1, 2, 4, 5, or 7, where: 1=6 inches, 2=12 inches, 4=18 inches, 5=24 inches, and 7=36 inches. ** For vent pipe section length, "xx" should be: 06, 09, 12, 18, 24, or 36 indicating the length of the vent pipe section in inches. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN Tel: 908-351-5400 www.haywardpool.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400
www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
17
Table 7
Vent Pipe & Terminal Specifications for Positive-Pressure Indoor Vent Kits
Kit Part Number
Heater
Model
Nominal Vent
Pipe Diameter
Vent TYpe
Vent Pipe
HoriZontal Vent
Terminal
Vertical Vent
Terminal
UHXPOSHZ11501
UHXPOSHZ12001
H150FD
H200FD
6 inch
Single-Wall
Heatfab Saf-T
Vent EZ Seal
P/N 960x *
Heatfab P/N
9614TERM
(elbow terminal)
and
5691CI (wall
penetration)
Heatfab P/N
5600CI
Double-Wall
Heatfab Saf-
T Vent CI Plus
P/N CCA06Lxx **
Heatfab P/N
9614TERM
(elbow terminal),
CCK06FC (collar),
CCA06ADSV
(connector ring),
and
CCL06WPNS
(wall penetration)
Heatfab P/N
CCA06RC
UHXPOSHZ12501
H250FD
6 inch
Single-Wall
Heatfab Saf-T
Vent EZ Seal
P/N 960x *
Heatfab P/N
5690CI
Heatfab P/N
5600CI
Double-Wall
Heatfab Saf-
T Vent CI Plus
P/N CCA06Lxx **
Heatfab P/N
CCE06WP
Heatfab P/N
CCA06RC
UHXPOSHZ13001
UHXPOSHZ13501
UHXPOSHZ14001
H300FD
H350FD
H400FD
8 inch
Single-Wall
Heatfab Saf-T
Vent EZ Seal
P/N 980x *
Heatfab P/N
5890CI
Heatfab P/N
5800CI
Double-Wall
Heatfab Saf-T
Vent CI Plus
P/N CCA08Lxx **
Heatfab P/N
CCE08WP
Heatfab P/N
CCA08RC
* For vent pipe section length, “x” should be:
1, 2, 4, 5, or 7, where: 1=6 inches, 2=12 inches, 4=18 inches, 5=24 inches, and 7=36 inches.
** For vent pipe section length, “xx” should be:
06, 09, 12, 18, 24, or 36 indicating the length of the vent pipe section in inches.