Hayward Universal H-Series Low NOx Service/Installation: H150FDN H200FDN H25 - Page 17
Table 7, Vent Pipe & Terminal Specifications for Positive-Pressure Indoor Vent Kits
View all Hayward Universal H-Series Low NOx manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
17 Table 7 Vent Pipe & Terminal Specifications for Positive-Pressure Indoor Vent Kits Kit Part Number UHXPOSHZ11501 UHXPOSHZ12001 UHXPOSHZ12501 UHXPOSHZ13001 UHXPOSHZ13501 UHXPOSHZ14001 Heater Model H150FD H200FD H250FD H300FD H350FD H400FD Nominal Vent Pipe Diameter 6 inch 6 inch 8 inch Vent Type Single-Wall Double-Wall Single-Wall Double-Wall Single-Wall Double-Wall Vent Pipe Heatfab Saf-T Vent EZ Seal P/N 960x * Heatfab SafT Vent CI Plus P/N CCA06Lxx ** Heatfab Saf-T Vent EZ Seal P/N 960x * Heatfab SafT Vent CI Plus P/N CCA06Lxx ** Heatfab Saf-T Vent EZ Seal P/N 980x * Heatfab Saf-T Vent CI Plus P/N CCA08Lxx ** Horizontal Vent Terminal Heatfab P/N 9614TERM (elbow terminal) and 5691CI (wall penetration) Heatfab P/N 9614TERM (elbow terminal), CCK06FC (collar), CCA06ADSV (connector ring), and CCL06WPNS (wall penetration) Heatfab P/N 5690CI Heatfab P/N CCE06WP Heatfab P/N 5890CI Heatfab P/N CCE08WP Vertical Vent Terminal Heatfab P/N 5600CI Heatfab P/N CCA06RC Heatfab P/N 5600CI Heatfab P/N CCA06RC Heatfab P/N 5800CI Heatfab P/N CCA08RC * For vent pipe section length, "x" should be: 1, 2, 4, 5, or 7, where: 1=6 inches, 2=12 inches, 4=18 inches, 5=24 inches, and 7=36 inches. ** For vent pipe section length, "xx" should be: 06, 09, 12, 18, 24, or 36 indicating the length of the vent pipe section in inches. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN Tel: 908-351-5400 www.haywardpool.com