HP 6125XLG R2306-HP 6125XLG Blade Switch TRILL Command Reference - Page 7

Examples, Table 4, Command output

Page 7 highlights

network-operator Examples # Display GR status information about TRILL. display trill graceful-restart status Restart status: RESTARTING Restart phase: LSDB synchronization Restart interval: 300s T3 remaining time: 140s Total number of interfaces: 1 Number of waiting LSPs: 3 T2 remaining time: 55s Interface: FortyGigE1/1/1 T1 remaining time: 2s RA received: Y CSNP received: N T1 expiration number: 1 Table 4 Command output Field Restart status Restart phase Restart interval T3 remaining time Total number of interfaces T2 remaining time Interface T1 remaining time RA received Description Restart status: • COMPLETE-GR is complete. • RESTARTING-GR of the Restart type is in process. • STARTING-GR of the Start type is in process. Restart phase: • Finish-GR is complete. • LSDB synchronization-T2 synchronization phase. • LSDB generation-LSP generation phase. • MCS synchronization-Layer 2 multicast data synchronization phase. • SPF-Route calculation phase. Restart interval (in seconds). Remaining time of the T3 timer (in seconds). The initial value is 65535 seconds, and is updated according to the remaining time in the RA packet. Total number of interfaces in the process. Remaining time of the T2 timer (in seconds). The initial value of the field is fixed at 60 seconds for GR of the Restart type and is the value (300 seconds by default) set by using the graceful-restart interval command for GR of the Start type. Port name. Remaining time of the T1 timer (in seconds). The initial value of the field is 3 seconds. RA received flag bit: • Y-Set. • N-Not set. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

4
network-operator
Examples
# Display GR status information about TRILL.
<Sysname> display trill graceful-restart status
Restart status: RESTARTING
Restart phase: LSDB synchronization
Restart interval: 300s
T3 remaining time: 140s
Total number of interfaces: 1
Number of waiting LSPs: 3
T2 remaining time: 55s
Interface: FortyGigE1/1/1
T1 remaining time: 2s
RA received: Y
CSNP received: N
T1 expiration number: 1
Table 4
Command output
Field
Description
Restart status
Restart status:
COMPLETE
—GR is complete.
RESTARTING
—GR of the Restart type is in process.
STARTING
—GR of the Start type is in process.
Restart phase
Restart phase:
Finish
—GR is complete.
LSDB
synchronization
—T2 synchronization phase.
LSDB
generation
—LSP generation phase.
MCS
synchronization
—Layer 2 multicast data synchronization phase.
SPF
—Route calculation phase.
Restart interval
Restart interval (in seconds).
T3 remaining time
Remaining time of the T3 timer (in seconds). The initial value is 65535 seconds,
and is updated according to the remaining time in the RA packet.
Total number of interfaces
Total number of interfaces in the process.
T2 remaining time
Remaining time of the T2 timer (in seconds). The initial value of the field is fixed
at 60 seconds for GR of the Restart type and is the value (300 seconds by
default) set by using the
graceful-restart interval
command for GR of the Start
type.
Interface
Port name.
T1 remaining time
Remaining time of the T1 timer (in seconds). The initial value of the field is 3
seconds.
RA received
RA received flag bit:
Y
—Set.
N
—Not set.