HP 8/40 Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 237
to validate the network, as root or run
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 237 highlights
28 FSS-1007 Probable Cause Indicates that the Ethernet connection between the active control processor (CP) and standby CP is not healthy. The error occurs when the standby CP does not respond to a request from the active CP within 5 seconds. This usually indicates a problem with the internal Ethernet connection and a disruption of the synchronization process. Recommended Action Check the Ethernet connection between active CP and standby CP (interface eth1) by issuing net commands such as ifconfig eth1 (as root) or run supportShow/supportSave to validate the network configuration; then try to restore the synchronization by issuing the haSyncStart command. If the problem persists, contact your switch service provider. Severity CRITICAL Fabric OS Message Reference 185 53-1000600-02