HP 8/40 Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 502
TRCE-1011, Probable Cause, Recommended, Action, supportFtp, supportSave, Severity, Message
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 502 highlights
73 TRCE-1011 Probable Cause Indicates that the trace daemon (traced), used for transferring trace files, failed to start. The trace capability within the switch is unaffected. The traced facility is normally restarted automatically by the system after a brief delay. Recommended Action If the message persists, reboot the CP (dual-CP system) or restart the switch. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR TRCE-1011 Message , [TRCE-1011], ,, INFO, , Trace dump manually transferred to target ' ': . Probable Cause Indicates that a manual transfer of trace dump files has occurred. Recommended No action is required. Action Severity INFO TRCE-1012 Message , [TRCE-1012], ,, WARNING, , The system was unable to retrieve trace information from slot . Probable Cause Indicates that communication between the main system and the indicated slot is unavailable. Recommended Check that the AP blade is enabled and retry the command. If the AP blade is already enabled, run Action the supportSave command and contact your switch service provider. Severity WARNING 450 Fabric OS Message Reference 53-1000600-02