HP 8/40 Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 496
SYSC-1004, Recommended, Action, chassisConfig, Severity, Message, Probable Cause, supportSave, reboot
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 496 highlights
71 SYSC-1004 It could also indicate that the current option number could not be read from the chassis option storage device (the world-wide name (WWN) card). This message occurs only on the Brocade 24000 and 48000. Recommended Action As indicated in the message, run the chassisConfig command to change to one that is valid on this platform running this firmware. Note that the chassisConfig option 1 should be valid for all platforms running any valid firmware. Severity CRITICAL SYSC-1004 Message , [SYSC-1004], ,, INFO, , Daemon restart successful Probable Cause Indicates that a terminated daemon is restarted by system automatically. Recommended Use the supportSave command to gather troubleshooting data. No further action is required. Action Severity INFO SYSC-1005 Message , [SYSC-1005], ,, WARNING, , Daemon is not restarted (Reason: ) Probable Cause Indicates that a terminated daemon is not restarted, either due to restart limit is reached or restart action fails Recommended Use the supportSave command to gather troubleshooting data. Issue a reboot or haFailover Action command to recover the system and limit the traffic disruption. Severity WARNING 444 Fabric OS Message Reference 53-1000600-02